Powered by GoogleTranslate

Inspection Detail

Inspection: 313387136 - Nestle Dreyers Ice Cream Company, Inc.

Inspection Information - Office: Bakersfield District Office

 

Inspection Nr: 313387136
Report ID: 0950647
Date Opened: 08/07/2012

Site Address:
Nestle Dreyers Ice Cream Company, Inc.
7301 District Blvd.
Bakersfield, CA 93313

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2024

NAICS: 311520/Ice Cream and Frozen Dessert Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/01/2012

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/27/2013


Related Activity
Type Activity Nr Safety Health
Accident 102626256
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $3,375 $0 $0 $5,375 $0 $8,750
Current Penalty $450 $0 $0 $375 $0 $825
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/02/2012 10/26/2012 $0 $5,000 $0 10/23/2012 J - ALJ Decision  
2. 01002 Other 3329 C 10/02/2012 10/26/2012 $375 $375 $0 -  
3. 02001 Serious 3400 F 10/02/2012 10/26/2012 $450 $3,375 $0 10/23/2012 J - ALJ Decision  

Investigation Summary

Investigation Nr: 202457669
Event: 04/23/2012
Employee Suffers 2nd Degree Burns When Scalded by Hot Water

At approximately 12:20 p.m. on April 23, 2012, Employee #1 reported to the Clean in Place (CIP) Unit #17, cold water pumping system, to perform routine maintenance work. The employee was preparing to inspect the in-line pipe screen for CIP Unit # 17, by opening the valve to drain water and removing the cap over the screen. Once the clamp holding the cap in place was released, extremely hot water burst out of the pipe, glanced off the surface of Unit # 16, and splashed onto Employee #1. The scalding hot water left the employee with severe burns to the abdomen, left hand and arm. Employee #1 immediately sought assistance and found another employee, who escorted the employee to the First Aid/Nursing Station located within the administrative offices complex. Emergency First Aid treatment was provided to Employee #1, and he was transported to Memorial Occupational Medicine Clinic, where Employee #1 was treated and was released for light duty for the following work day. Employee #1 became aware that his condition was not improving, and returned to Memorial Occupational Medicine Clinic, for further medical care. The employee was examined, and then referred to a Medical Burn Specialist at San Joaquin Community Hospital/Grossman Burn Center in Bakersfield. Employee #1 was found to have serious 2nd degree burns that required extensive treatment, surgery, and five days of hospital care.

Keywords: BURN, ABDOMEN, CLEANING, PIPE, WATER PIPE, ARM, HOT WATER, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313387136 Hospitalized injury Burn/Scald(Heat) Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.