Powered by GoogleTranslate

Inspection Detail

Inspection: 313382020 - Jmi Sanitation Service Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 313382020
Report ID: 0950642
Date Opened: 07/20/2010

Site Address:
Jmi Sanitation Service Inc
4020 Compton Ave
Los Angeles, CA 90011

Mailing Address:
12872 Clemson Dr, Corona, CA 92880

Union Status: NonUnion

SIC:7349

NAICS: 561790/Other Services to Buildings and Dwellings


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/20/2010

Emphasis:

Case Closed: 02/15/2011


Related Activity
Type Activity Nr Safety Health
Accident 102622263
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $860 $0 $860
Current Penalty $0 $0 $0 $860 $0 $860
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 12/20/2010 01/22/2011 $310 $310 $0 -  
2. 01002 Other 3314 C 12/20/2010 12/23/2010 $550 $550 $0 -  

Investigation Summary

Investigation Nr: 202456794
Event: 07/12/2010
Employee Amputates Finger in Metal Detection Machine

At approximately 4:00 p.m. on July 12, 2010, an employee was performing his duties of employment as equipment cleaner. The work was conducted after normal business hours. At the time of the incident, the employee was cleaning a portion of a raw ground meat line that detected and removed foreign material within the product. The system was manufactured by Safeline, was an electrical and pneumatic system operating at 110V and 150 psi respectively and was comprised of a metal detection and X-ray inspection module serial number 2958501E and a reject mechanism serial number 928138.005.009. This unit was a stand-alone system that had a single power source supplied by a flexible cord. When foreign material was detected in a portion of ground meat, the inspection module sends a signal to activate the reject mechanism. This reject mechanism, resembling a ball valve through which the meat passed, turned 90 degrees cutting of the contaminated portion which was then pushed out to a waste bin. It was this reject mechanism that the employee was cleaning. With the inspection module energized as well as connected to the reject mechanism, the employee began to dissemble the reject mechanism. As a coworker attempted to unscrew the ball valve, the reject mechanism activated closing on his middle finger resulting in an amputation near the first knuckle. The employee was hospitalized and treated for finger amputation.

Keywords: JANITOR, AMPUTATED, FINGER, CLEANING, CAUGHT BY, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313382020 Hospitalized injury Amputation Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close