Powered by GoogleTranslate

Inspection Detail

Inspection: 313350019 - Bowman'S Inc. Of Mountain Home

Inspection Information - Office: Boise Area Office

 

Inspection Nr: 313350019
Report ID: 1032500
Date Opened: 09/16/2009

Site Address:
Bowman'S Inc. Of Mountain Home
N Gathe Drive
Pocatello, ID 83201

Mailing Address:
Po Box 850, Mountain Home, ID 83647

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/22/2009

Emphasis: N:Trench, S:Commercial Constr, S:Powered Ind Vehicle, S:Trenching

Case Closed: 03/01/2016


Related Activity
Type Activity Nr Safety Health
Accident 361893969
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $9,500 $35,000 $0 $0 $0 $44,500
Current Penalty $6,000 $14,000 $0 $0 $0 $20,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260651 B04 03/09/2010 03/15/2010 $2,000 $3,500 $0 03/31/2010 F - Formal Settlement  
2. 01002A Serious 19260651 C02 03/09/2010 03/15/2010 $2,000 $3,500 $0 03/31/2010 F - Formal Settlement  
3. 01002B Serious 19260652 G01 III 03/09/2010 03/15/2010 $0 $0 $0 03/31/2010 F - Formal Settlement  
4. 01003 Serious 19260652 G01 II 03/09/2010 03/15/2010 $2,000 $2,500 $0 03/31/2010 F - Formal Settlement  
5. 02001A Willful 19260651 K02 03/09/2010 03/15/2010 $14,000 $35,000 $0 03/31/2010 F - Formal Settlement  
6. 02001B Willful 19260652 A01 03/09/2010 03/15/2010 $0 $0 $0 03/31/2010 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200232338
Event: 09/16/2009
Employee Is Killed When Trench Caves In

On September 16, 2009, Employee #1 was laying pipe in a 9 ft deep trench. He was connecting two sections of 12 in. diameter by 14 feet long pipe. The pipe end was lubed and Employee #1 left the protection of the trench shield to push the pipes together from the end not being connected. The first attempt to connect the pipes from a standing position was unsuccessful. Employee #1 sat down to kick and push the pipes together using his legs. Immediately after he pushed the pipes together, a cave-in occurred from the upper portion of the trench wall that was near an existing gas supply line. Employee #1 was buried and killed.

Keywords: TRENCH BOX, TRENCH, PIPE, BURIED, CAVE-IN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313350019 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close