Inspection Detail
Inspection: 313350019 - Bowman'S Inc. Of Mountain Home
Inspection Information - Office: Boise Area Office
Site Address:
Bowman'S Inc. Of Mountain Home
N Gathe Drive
Pocatello, ID 83201
Mailing Address:
Po Box 850, Mountain Home, ID 83647
Union Status: NonUnion
SIC:1623
NAICS: 237110/Water and Sewer Line and Related Structures Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/22/2009
Emphasis: N:Trench, S:Commercial Constr, S:Powered Ind Vehicle, S:Trenching
Case Closed: 03/01/2016
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361893969 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $9,500 | $35,000 | $0 | $0 | $0 | $44,500 |
Current Penalty | $6,000 | $14,000 | $0 | $0 | $0 | $20,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260651 B04 | 03/09/2010 | 03/15/2010 | $2,000 | $3,500 | $0 | 03/31/2010 | F - Formal Settlement | |
2. | 01002A | Serious | 19260651 C02 | 03/09/2010 | 03/15/2010 | $2,000 | $3,500 | $0 | 03/31/2010 | F - Formal Settlement | |
3. | 01002B | Serious | 19260652 G01 III | 03/09/2010 | 03/15/2010 | $0 | $0 | $0 | 03/31/2010 | F - Formal Settlement | |
4. | 01003 | Serious | 19260652 G01 II | 03/09/2010 | 03/15/2010 | $2,000 | $2,500 | $0 | 03/31/2010 | F - Formal Settlement | |
5. | 02001A | Willful | 19260651 K02 | 03/09/2010 | 03/15/2010 | $14,000 | $35,000 | $0 | 03/31/2010 | F - Formal Settlement | |
6. | 02001B | Willful | 19260652 A01 | 03/09/2010 | 03/15/2010 | $0 | $0 | $0 | 03/31/2010 | F - Formal Settlement |
Investigation Summary
On September 16, 2009, Employee #1 was laying pipe in a 9 ft deep trench. He was connecting two sections of 12 in. diameter by 14 feet long pipe. The pipe end was lubed and Employee #1 left the protection of the trench shield to push the pipes together from the end not being connected. The first attempt to connect the pipes from a standing position was unsuccessful. Employee #1 sat down to kick and push the pipes together using his legs. Immediately after he pushed the pipes together, a cave-in occurred from the upper portion of the trench wall that was near an existing gas supply line. Employee #1 was buried and killed.
Keywords: TRENCH BOX, TRENCH, PIPE, BURIED, CAVE-IN
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 313350019 | Fatality | Asphyxia | Occupation not reported |