Powered by GoogleTranslate

Inspection Detail

Inspection: 313104382 - Master Mechanical Services, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 313104382
Report ID: 0418800
Date Opened: 08/20/2009

Site Address:
Master Mechanical Services, Inc.
405 West 49th Street
Hialeah, FL 33012

Mailing Address:
15181 Nw 33 Pl, Miami, FL 33054

Union Status: NonUnion

SIC:1799

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/18/2009

Emphasis:

Case Closed: 04/06/2010


Related Activity
Type Activity Nr Safety Health
Accident 100681477
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $9,400 $0 $0 $0 $0 $9,400
Current Penalty $7,050 $0 $0 $0 $0 $7,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 12/18/2009 12/31/2009 $550 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260403 I02 I 12/18/2009 12/23/2009 $550 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19260404 F06 12/18/2009 12/29/2009 $550 $750 $0 I - Informal Settlement  
4. 01004 Serious 19260405 G01 II 12/18/2009 12/29/2009 $500 $750 $0 I - Informal Settlement  
5. 01005 Serious 19260416 A01 12/18/2009 12/29/2009 $4,900 $4,900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200677912
Event: 08/20/2009
Worker Is Electrocuted and Killed While Repairing Arc Welder

At approximately 12:50 p.m. on August 20, 2009, Employee #1, an air conditioning mechanic with Master Mechanical Services, Inc., was repairing an arc welder. While repairing the 110 volt wire-fed, Lincoln Arc Welder, he did not unplug the unit from an energized ungrounded extension cord. Employee #1 touched the live part of the welder and was electrocuted.

Keywords: ELECTROCUTED, WELDER, CONSTRUCTION, GROUND FAULT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313104382 Fatality Electric Shock Heating, air conditioning, and refrig. mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close