Powered by GoogleTranslate

Inspection Detail

Inspection: 313090052 - Fort Smith Garage Door Company

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 313090052
Report ID: 0627100
Date Opened: 07/21/2009

Site Address:
Fort Smith Garage Door Company
138 Dogwood Lp.
Alma, AR 72921

Mailing Address:
5901 S 26th Cir, Ft Smith, AR 72908

Union Status: NonUnion

SIC:3442

NAICS: 332321/Metal Window and Door Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 07/30/2009

Planning Guide: Safety-Construction

Emphasis: S:Electrical

Case Closed: 06/15/2010


Related Activity
Type Activity Nr Safety Health
Accident 100265297
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $2,700 $0 $0 $0 $0 $2,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 08/06/2009 08/11/2009 $900 $1,500 $0 I - Informal Settlement  
2. 01001B Serious 19260351 D04 08/06/2009 08/11/2009 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19260351 A02 08/06/2009 08/11/2009 $900 $1,500 $0 I - Informal Settlement  
4. 01003 Serious 19260351 D01 08/06/2009 08/11/2009 $900 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 100265297
Event: 07/21/2009
Employee Is Killed When Electrocuted by Generator

On July 21, 2009, Employee #1 was installing a commercial garage door. He was using a Champion 16 welder as a generator to provide A/C power to charge his cordless tool batteries and to power his chop saw. The welding leads were not stored properly, and the insulation on the end of the positive electrode/stinger was missing. The positive electrode/stinger was loosely wrapped on its hanger and was in direct contact with the bed of the truck. The negative ground clamp was also loosely wrapped on its hanger, but was not touching the bed of the truck. When Employee #1 crawled into the back of the truck while the welder was running, he contacted the negative lead with his right arm. He was electrocuted when his body became the path of least resistance to the ground. He was killed.

Keywords: ELEC INSULATION, ELECTROCUTED, WELDING ELECTRODE, GROUNDING ELECTRODE, ELECTRIC GENERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313090052 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.