Powered by GoogleTranslate

Inspection Detail

Inspection: 313034449 - C & C Welding Inc.

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 313034449
Report ID: 0627100
Date Opened: 05/13/2009

Site Address:
C & C Welding Inc.
194 Tank Farm Road
Garner, AR 72052

Mailing Address:
300 West Dixie Ave., Suite 6, Elizebethtown, KY 42701

Union Status: NonUnion

SIC:3441

NAICS: 332312/Fabricated Structural Metal Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/06/2009

Planning Guide: Safety-Construction

Emphasis: S:Constr6

Case Closed: 12/11/2009


Related Activity
Type Activity Nr Safety Health
Accident 100265263
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 1 3
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $3,000 $0 $0 $1,500 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/05/2009 12/07/2009 $1,500 $1,500 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 5A0001 11/05/2009 12/07/2009 $1,500 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 5A0001 11/05/2009 12/07/2009 $1,500 $1,500 $0 I - Informal Settlement  
4. 01004 Other 5A0001 11/05/2009 12/07/2009 $1,500 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200263614
Event: 05/12/2009
Workers Are Ejected from Exploding Gasoline Stoarge Tank

On May 12, 2009, three workers were in a 57,000 barrel capacity gasoline storage tank preparing to install a remote fuel level gauging rod. Shortly after the workers entered the tank to begin this process, the tank exploded, ejecting the top half of the roof, along with the three workers, up and through the geodesic dome to the exterior grounds surrounding the tank. The tank was equipped with two roofing systems. The interior, hollow "floating" roof was approximately 32 inches thick, 100 feet in diameter and was resting upon 6-foot tall legs at the bottom of the 49-foot-high tank. The exterior roof, a geodesic dome consisted of an aluminum skeleton, paneled with Plexiglas polygons.

Keywords: EJECTED, INSTALLING, ROOF, EXPLOSION, GASOLINE, STORAGE AREA, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313034449 Fatality Other Occupation not reported
2 313034449 Fatality Other Occupation not reported
3 313034449 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.