Powered by GoogleTranslate

Inspection Detail

Inspection: 313016693 - Foltz Welding, Ltd.

Inspection Information - Office: Fairview Heights Area Office

 

Inspection Nr: 313016693
Report ID: 0524530
Date Opened: 08/24/2010

Site Address:
Foltz Welding, Ltd.
8200 Farthing Road South Side Of Tank 1011
Vernon, IL 62892

Mailing Address:
Po Box 38, Patoka, IL 62875

Union Status: Union

SIC:1799

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/2010

Emphasis: L:Piv, S:Commercial Constr, S:Powered Ind Vehicle, S:Struck-By

Case Closed: 01/24/2011


Related Activity
Type Activity Nr Safety Health
Accident 100842541
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,500 $0 $0 $0 $0 $3,500
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260251 A01 12/08/2010 12/13/2010 $3,500 $3,500 $0 -  
2. 01001B Serious 19260251 E08 III 12/08/2010 12/13/2010 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200841914
Event: 08/23/2010
Employee Dies after Being Struck in Head by Pipe

At approximately 5:00 p.m. on August 23, 2010, Employee #1, a pipefitter, was working with a crew of five pipefitters and one operator, moving a long section of 8-inch high density polyethylene (HDPE) pipe into position onto a McElroy Manufacturing Fusion Machine, MN 6-12. The crew was staging the part to weld a flange and Chicago fitting onto the end of the 8-inch HDPE the following day. This was being done to provide water for a hydrotest of fabricated process piping prior to being placed into service per applicable API mechanical integrity standards. The 8-inch HDPE pipe was being run from a retention pond several hundred yards to the north, and had previously been used to run water elsewhere on the new construction project. There was standing water in the charged line. The crew cut the 8-inch HDPE pipe and rigged a 12-ft endless synthetic web sling to the bucket of a Caterpillar 346 CL. The cab of the Caterpillar 346 CL was positioned 21 feet from the McElroy fusion machine. As the Caterpillar operator began to drag the long section of 8-inch HDPE into position, his primary attention was focused on watching the movement of the pipe on the ground. As the forward section was elevated by the endless sling, rigged 10-ft to 15-ft from the end of the pipe in a choker hitch, the sling slid out of the wet/smooth surface of the 8-inch HDPE pipe. The pipe struck Employee #1 in the head with such force that it broke the suspension of his Bullard MN S-71 protective helmet. He died as a result of the blow to his head.

Keywords: HEAD, HARD HAT, HOISTING MECHANISM, PPE, PIPE, STRUCK BY, SLING, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 313016693 Fatality Bruise/Contus/Abras Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.