Inspection Detail
Inspection: 312979750 - Brian'S Professional Cleaning & Restoration Co Inc
Inspection Information - Office: Allentown Area Office
Site Address:
Brian'S Professional Cleaning & Restoration Co Inc
623 Williams Street
Bethlehem, PA 18015
Mailing Address:
235 South Broad Street, Nazareth, PA 18064
Union Status: NonUnion
SIC:1751
NAICS: 238350/Finish Carpentry Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/30/2010
Planning Guide: Safety-Construction
Emphasis: L:Fall, L:Rescon, S:Fall From Height, S:Residential Constr
Case Closed: 02/03/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101322105 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 5 | ||||
| Current Violations | 5 | 5 | ||||
| Initial Penalty | $10,000 | $0 | $0 | $0 | $0 | $10,000 |
| Current Penalty | $6,000 | $0 | $0 | $0 | $0 | $6,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260416 A01 | 07/20/2010 | 08/04/2010 | $1,500 | $2,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260451 F06 | 07/20/2010 | 07/23/2010 | $750 | $1,250 | $0 | I - Informal Settlement | ||
| 3. | 01003A | Serious | 19260451 B03 | 07/20/2010 | 07/23/2010 | $750 | $1,250 | $0 | I - Informal Settlement | ||
| 4. | 01003B | Serious | 19260452 J02 | 07/20/2010 | 07/23/2010 | $0 | $0 | $0 | - | ||
| 5. | 01004 | Serious | 19260451 G01 | 07/20/2010 | 08/04/2010 | $1,500 | $2,500 | $0 | I - Informal Settlement | ||
| 6. | 01005 | Serious | 19260501 B13 | 07/20/2010 | 07/23/2010 | $1,500 | $2,500 | $0 | I - Informal Settlement |
Investigation Summary
An employee was framing out the rough opening for a replacement window. The employee fell from the opening approximately 6.7 meters to the ground. During the fall, the employee struck the single aluminum plank of a pump-jack scaffold erected approximately 2.1 meters below the window opening, then pitched backward falling to the concrete sidewalk. He struck his head on the sidewalk. He was later pronounced dead at the hospital. The coroner's report indicated that the employee had received an electric shock. Further investigation revealed that the employee, who had his foot on a cast-iron radiator, had been holding a steel tape measure. The tape measure had contacted a nearby 7.2-kilovolt overhead power line. The coroner ruled cause of death as blunt trauma with an additional cause of electrocution.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, MEASURING DEVICE, E C, ELECTRIC SHOCK, FALL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312979750 | Fatality | Bruise/Contus/Abras | Carpenters |