Powered by GoogleTranslate

Inspection Detail

Inspection: 312913304 - Cal Citrus Packing Co

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 312913304
Report ID: 0950625
Date Opened: 11/20/2009

Site Address:
Cal Citrus Packing Co
460 Valencia St
Lindsay, CA 93247

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:0723

NAICS: 115114/Postharvest Crop Activities (except Cotton Ginning)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/10/2010

Emphasis: S:Agriculture (Aship)

Case Closed: 08/06/2010


Related Activity
Type Activity Nr Safety Health
Accident 362279242
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $1,175 $0 $1,175
Current Penalty $0 $0 $0 $1,175 $0 $1,175
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 05/13/2010 06/15/2010 $160 $160 $0 -  
2. 01002 Other 3662 05/13/2010 06/15/2010 $650 $650 $0 -  
3. 01003 Other 3668 A01 05/13/2010 06/15/2010 $365 $365 $0 -  
4. 01004 Other 5155 E01 05/13/2010 06/15/2010 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201493574
Event: 11/19/2009
Three Employees Are Exposed to Carbon Monoxide

On November 20, 2009, Employee #1, #2 and #3 were performing a pallet inventory check inside a 65,000 square foot cold storage room, using a S30 Hyster forklift. The cold room is a closed environment with recirculated air. It has two doors that are opposite of each other and each door is equipped with a pleated drive through plastic curtain. After working in the cold room for approximately 45 to 60 minutes, the three employees became ill. Employee #1 and #3 manifested clinical signs of carbon monoxide exposure, and Employee #2 became unconscious, with gurgling. Employee #1 and #2 were air lifted to Fresno Community Regional Medical Center, while Employee #3 was taken to Sierra View Hospital. The supervisor was in the cold room at the beginning of the inventory check and noted that the forklift was operating properly. Upon reentry into the cold room, the supervisor noted that the south exterior door was closed, which is in conflict with the employer's directives. The forklift appeared to be in good repair and was maintained on a regular schedule by PEPE Materials Handling, a Hyster franchisor. A PEPE forklift technician, using an exhaust analyzer, determined that the carbon monoxide output was 8, which is above the allowable exhaust emissions of 2, that is established in 8CCR 5145(c) for a 100 to 140 cubic-inch internal combustion engine. The combination of carbon monoxide emissions, in conjunction with the closed doors, was identified as the cause of exposure. Employee #1 was hospitalized for treatment, while Employee #2 and #3 were treated, and then were released.

Keywords: ENCLOSED SPACE, LUNG, VAPOR, WORK RULES, INHALATION, STORAGE ROOM, INDUSTRIAL TRUCK, POISONING, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312913304 Hospitalized injury Poisoning(Systemic) Laborers, except construction
2 312913304 Non Hospitalized injury Poisoning(Systemic) Laborers, except construction
3 312913304 Non Hospitalized injury Poisoning(Systemic) Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close