Powered by GoogleTranslate

Inspection Detail

Inspection: 312883283 - Gutters For Less Incorporated

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 312883283
Report ID: 0352440
Date Opened: 05/13/2009

Site Address:
Gutters For Less Incorporated
3605 Ligon Road
Ellicott City, MD 21043

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1761

NAICS: 238390/Other Building Finishing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/24/2009

Planning Guide: Safety-Construction

Emphasis: L:Electric, L:Fall, S:Construction (1500-1799)

Case Closed: 08/28/2009


Related Activity
Type Activity Nr Safety Health
Accident 102363421
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $5,500 $0 $0 $0 $0 $5,500
Current Penalty $2,070 $0 $0 $0 $0 $2,070
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A01 07/24/2009 08/03/2009 $1,035 $2,750 $0 I - Informal Settlement  
2. 01002 Serious 19260416 A03 07/24/2009 08/03/2009 $1,035 $2,750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202502514
Event: 05/13/2009
Electric Shock - Contact with Overhead Line thru Gutter

A carpenter working for a gutter company was hanging a piece of aluminum gutter 14 feet long. He was working from a 28-foot aluminum extension ladder, and he was approximately 20 feet above the ground. Suddenly, the aluminum gutter he was holding contacted an overhead power line energized at 13,200 volts. He sustained burns to his hand, chest, arms, and legs around both knees. He then fell approximately 16 feet to the ground. He was transported to Howard County General Hospital, where he was pronounced dead on arrival. He had been electrocuted.

Keywords: E GI III, EXTENSION LADDER, OVERHEAD POWER LINE, ELECTRICAL, CARPENTER, ELECTROCUTED, CONSTRUCTION, E C, E GI IC, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312883283 Fatality Electric Shock Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close