Powered by GoogleTranslate

Inspection Detail

Inspection: 312862253 - Parkway Iron & Metal Co., Inc. Dba Park Stein

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 312862253
Report ID: 0214500
Date Opened: 11/20/2009

Site Address:
Parkway Iron & Metal Co., Inc. Dba Park Stein
613-639 Route 46 East
Clifton, NJ 07015

Mailing Address:
613-639 Route 46 East / Po Box 2399, Clifton, NJ 07015

Union Status: NonUnion

SIC:5093

NAICS: 423930/Recyclable Material Merchant Wholesalers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/08/2010

Emphasis:

Case Closed: 04/26/2010


Related Activity
Type Activity Nr Safety Health
Referral 202659694 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $4,000 $0 $0 $0 $0 $4,000
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 A 03/24/2010 04/19/2010 $1,000 $2,000 $0 I - Informal Settlement  
2. 01001B Serious 19100132 D01 03/24/2010 04/19/2010 $0 $0 $0 I - Informal Settlement  
3. 01002A Serious 19100253 A04 03/24/2010 04/19/2010 $1,000 $2,000 $0 I - Informal Settlement  
4. 01002B Serious 19101200 G08 03/24/2010 03/29/2010 $0 $0 $0 I - Informal Settlement  
5. 01002C Serious 19101200 H01 03/24/2010 03/29/2010 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201381191
Event: 11/11/2009
Employee Is Burned When Cutting Torch Explodes

On November 11, 2009, Employee #1 was cutting 1.5-in.-thick scrap steel with a torch in a designated cutting area of a scrap yard. The weather conditions were: 54 degrees Fahrenheit, 45% humidity, clear sky with 10 mile visibility, and 12.7 mph north winds with gusts up to 16.1 mph. The torch was a 36-in.-long Harris-style 6200 oxygen-propylene cutting torch with a 70 degree head. Another cutting employee was working in the area. Employee #1 was wearing a hard hat, shaded goggles, gauntlet welding gloves, safety shoes, and cotton clothing, none of which was flame-resistant. An explosion occurred near the torch's gas inlet hoses. Employee #1 was hospitalized at Saint Barnabas Burn Center for burns (up to third-degree) to his torso, right arm, and face (approximately 15% of his body surface area).

Keywords: BURN, CLOTHING, OXYGEN, PPE, FIRE, TORCH, EXPLOSION, SCRAP METAL, PROPYLENE, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312862253 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.