Inspection Detail
Inspection: 312796964 - Coleman Co., Inc.
Inspection Information - Office: Wichita Area Office
Site Address:
Coleman Co., Inc.
5605 N. 119th W.
Maize, KS 67101
Mailing Address:
P.O. Box 2931, Wichita, KS 67201
Union Status: NonUnion
SIC:3499
NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/21/2009
Emphasis: N:Psmpqv, S:Electrical
Case Closed: 03/18/2009
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 202930145 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 H07 IA | 02/23/2009 | 03/30/2009 | $2,500 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 1:15 p.m. on January 19, 2009, Employee #1 was working on the water bath line degassing a cylinder of propylene in a cabinet designed for this activity. An explosion occurred caused by static electricity. Employee #1 received burns to his face and both hands and was hospitalized.
Keywords: FLAMMABLE LIQUID, FLAMMABLE VAPORS, EXPLOSION, CHEMICAL VAPOR, FACE, HAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 312796964 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |