Inspection Detail
Inspection: 312760044 - Hp Communications, Inc.
Inspection Information - Office: Fremont District Office
Site Address:
Hp Communications, Inc.
W. Alma And Michigan
San Jose, CA 95112
Mailing Address:
13341 Temescal Canyon Rd., Corona, CA 92883
Union Status: NonUnion
SIC:1731
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/10/2009
Emphasis:
Case Closed: 10/08/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102605987 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $21,375 | $0 | $0 | $0 | $0 | $21,375 |
| Current Penalty | $0 | $0 | $0 | $2,000 | $0 | $2,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 8615 C01 | 09/10/2009 | 10/28/2009 | $0 | $3,375 | $0 | 10/23/2009 | D - Govt Dismissed | Citation has been deleted. |
| 2. | 02001 | Other | 8615 C02 | 09/10/2009 | 10/28/2009 | $2,000 | $18,000 | $0 | 10/23/2009 | D - Govt Dismissed |
Investigation Summary
At approximately 11:40 a.m. on March 11, 2009, Employee #1, with Hp Communications, Inc., was on a telephone when he received a 24 KV electrical shock. He was hospitalized at Santa Clara Valley Medical Center for treatment.
Keywords: BURN, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312760044 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |