Inspection Detail
Inspection: 312759640 - Qualified Maintenance, Inc.
Inspection Information - Office: Fremont District Office
Site Address:
Qualified Maintenance, Inc.
270 Sunol Street
San Jose, CA 95126
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7349
NAICS: 561720/Janitorial Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/28/2009
Emphasis:
Case Closed: 09/21/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102605615 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $960 | $0 | $960 |
| Current Penalty | $0 | $0 | $0 | $960 | $0 | $960 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328 H | 06/17/2009 | 08/04/2009 | $410 | $410 | $0 | - | ||
| 2. | 01002 | Other | 3577 E | 06/17/2009 | 06/22/2009 | $275 | $275 | $0 | - | ||
| 3. | 01003 | Other | 4650 E | 06/17/2009 | 06/22/2009 | $275 | $275 | $0 | - |
Investigation Summary
At approximately 9:00 a.m. on January 22, 2009, Employee #1, a Mechanic, had disconnected a gas line and was allowing the gas to pour into a 16 inch oil pan, when a piece of towel that he was using to clean his hands fell from his hands and fell through the motor and caught on fire. This towel which caught on fire then landed in the oil pan that was filled with gas. When Employee #1 saw the oil pan ignite, his first reaction was to pull it away from the vehicle. As he pulled the burning oil pan away from below the vehicle the liquid, spilled and burned both of his hands. Employee #1 blew his hands off, wiped them on his sweater and then used the fire extinguisher to put the fire out in the oil pan. Employee #1 notified the office manager, who advised the safety director to transport Employee #1 to the Valley Medical center. Employee #1 was admitted for one day for observation.
Keywords: BURN, MECHANIC, LUBRICATING FLUID, GASOLINE, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312759640 | Hospitalized injury | Burn(Chemical) | Occupation not reported |