Inspection Detail

Inspection: 312695331 - Thyssenkrupp Elevator Corporation

Inspection Information - Office: San Francisco District Office

 

Inspection Nr: 312695331
Report ID: 0950611
Date Opened: 05/03/2013

Site Address:
Thyssenkrupp Elevator Corporation
1190 Mission Street
San Francisco, CA 94103

Mailing Address:
14400 Catalin Street, Sn Leandro, CA 94577

Union Status: Union

SIC:3534

NAICS: 333921/Elevator and Moving Stairway Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/10/2013

Emphasis:

Case Closed: 10/30/2013


Related Activity
Type Activity Nr Safety Health
Accident 102825577
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $375 $0 $375
Current Penalty $0 $0 $0 $375 $0 $375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 09/12/2013 09/17/2013 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 201186962
Event: 03/23/2013
Elevator Mechanic Gets Hand Caught, Crushed in Hoistway

At approximately 5:30 a.m. on March 23, 2013, Employee #1, a 42-year-old male journeyman construction elevator mechanic with Thyssenkrupp Elevator Corporation was working alone on car top of a newly installed passenger elevator in a building that was under construction. Employee #1 was installing wiring to the electric eye operator of the car door. The sensor would travel pass the various angle brackets on each floor in the hoistway to let the elevator controller "know" which floor the car is located at. Employee #1 moved the car by actuating a pendant station (remote control switch) with his left hand, his right little finger which was placed between a U-shaped metal sensor mounted on the car top against a stationary metal angle bracket that was mounted on the hoistway was crushed. Employee #1 stopped the car and got off the car top. Employee #1 called another mechanic who was working on an adjacent hoistway. The mechanic drove Employee #1 to the San Francisco General Hospital. There were no witnesses to Employee #1's incident. Employee #1 was treated for a crushed finger and was hospitalized for four days. The regional safety manager for Thyssenkrupp Elevator Corporation was interviewed during the course of the investigation however Employee #1 could not be reached.

Keywords: CABLE TRAY, WIRE ROPE, FINGER, MECHANIC, NIP POINT, ELEVATOR, ELEVATOR SHAFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312695331 Hospitalized injury Amputation Elevator installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close