Inspection Detail
Inspection: 312677719 - Aerotek
Inspection Information - Office: San Diego District Office
Site Address:
Aerotek
3050 Science Park Drive
La Jolla, CA 92037
Mailing Address:
9353 Fairway View Place, Suite #160, Rancho Cucamonga, CA 91730
Union Status: NonUnion
SIC:7363
NAICS: 561320/Temporary Help Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/30/2009
Emphasis:
Case Closed: 09/27/2010
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101076131 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $18,000 | $0 | $0 | $700 | $0 | $18,700 |
| Current Penalty | $0 | $0 | $0 | $5,560 | $0 | $5,560 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 10/01/2009 | 11/03/2009 | $335 | $420 | $0 | 11/02/2009 | F - Formal Settlement | |
| 2. | 01002 | Other | 3203 A07 | 10/01/2009 | 11/03/2009 | $225 | $280 | $0 | 11/02/2009 | F - Formal Settlement | |
| 3. | 02001 | Other | 3383 A | 10/01/2009 | 10/21/2009 | $5,000 | $18,000 | $0 | 11/02/2009 | F - Formal Settlement |
Investigation Summary
At approximately 8:00 a.m. on April 6, 2009, Employee #1, an animal technician, was working at a research facility. Employee #1 and a coworker began setting up the cage washer (a large industrial automatic dishwashing machine) to clean animal cages. There is a clean out pipe on the side of the machine where there is a filter used to catch solid debris. The clean-out pipe was cleaned the Friday before. It has a clamp which holds the lid in place over the pipe. Employee #1 turned on the machine to heat up the water. Once the water reached 185 degrees Fahrenheit at the rinse side, he turned on the pump. As Employee #1 was getting ready to load the machine he went to move a rack of bottles toward the front of the machine. The cap on the clean-out pipe blew off. The pipe sprayed hot water and steam on Employee #1, hitting him in the groin and upper right thigh, causing second-degree burns. Employee #1 was not wearing an apron or boots at the time. Employee #1 was hospitalized for approximately ten days.
Keywords: BURN, HEAT, PPE, CLEANING, THIGH, STEAM, HOT TAR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312677719 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |
Translate