Inspection Detail
Inspection: 312667835 - Mag Instrument Inc
Inspection Information - Office: Monrovia District Office
Site Address:
Mag Instrument Inc
2001 S Hellman Ave
Ontario, CA 91761
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3648
NAICS: 335129/Other Lighting Equipment Manufacturing
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 02/10/2012
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 09/10/2012
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102714151 | ||
| Complaint | 207211343 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $18,000 | $0 | $0 | $5,745 | $0 | $23,745 |
| Current Penalty | $0 | $0 | $0 | $7,000 | $0 | $7,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 02/10/2012 | 03/14/2012 | $5,000 | $5,000 | $0 | 02/21/2012 | F - Formal Settlement | |
| 2. | 01002 | Other | 3203 A04 B | 02/10/2012 | 03/14/2012 | $0 | $560 | $0 | 02/21/2012 | F - Formal Settlement | |
| 3. | 01003 | Other | 5194 F04 | 02/10/2012 | 03/14/2012 | $0 | $185 | $0 | 02/21/2012 | F - Formal Settlement | Citation has been deleted. |
| 4. | 02001 | Other | 3328 B | 02/10/2012 | 02/20/2012 | $2,000 | $18,000 | $0 | 02/21/2012 | F - Formal Settlement |
Investigation Summary
At approximately 1:15 p.m. on August 31, 2011, Employee #1, a tool and die CNC operator, was at a Mori Seiki CNC vertical milling machine, Model Number SV-500/40; Serial Number 1318. The machine was set up for the trimming process. The interlock on the doors had been defeated allowing the equipment to operate with the doors open. The indicator, used for centering the work piece, was attached to the indicator holder which was attached to the machine's spindle. He inadvertently activated the machine and it reached approximately 6000 to 6500 RPM, causing the indicator to disengage from the machine. The indicator flew out the open doors of the machine and struck Employee #1 in the shoulder. Employee #1 was hospitalized and received surgery for a deep laceration to his right shoulder.
Keywords: SHOULDER, LACERATION, STRUCK BY, UNGUARDED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312667835 | Hospitalized injury | Cut/Laceration | Numerical control machine operators |