Powered by GoogleTranslate

Inspection Detail

Inspection: 312667835 - Mag Instrument Inc

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 312667835
Report ID: 0950636
Date Opened: 08/31/2011

Site Address:
Mag Instrument Inc
2001 S Hellman Ave
Ontario, CA 91761

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3648

NAICS: 335129/Other Lighting Equipment Manufacturing


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 02/10/2012

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 09/10/2012


Related Activity
Type Activity Nr Safety Health
Accident 102714151
Complaint 207211343 Yes Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 3 3
Initial Penalty $18,000 $0 $0 $5,745 $0 $23,745
Current Penalty $0 $0 $0 $7,000 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/10/2012 03/14/2012 $5,000 $5,000 $0 02/21/2012 F - Formal Settlement  
2. 01002 Other 3203 A04 B 02/10/2012 03/14/2012 $0 $560 $0 02/21/2012 F - Formal Settlement  
3. 01003 Other 5194 F04 02/10/2012 03/14/2012 $0 $185 $0 02/21/2012 F - Formal Settlement Citation has been deleted.
4. 02001 Other 3328 B 02/10/2012 02/20/2012 $2,000 $18,000 $0 02/21/2012 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202477691
Event: 06/30/2011
Employee's Shoulder Lacerated by Flying Object

At approximately 1:15 p.m. on August 31, 2011, Employee #1, a tool and die CNC operator, was at a Mori Seiki CNC vertical milling machine, Model Number SV-500/40; Serial Number 1318. The machine was set up for the trimming process. The interlock on the doors had been defeated allowing the equipment to operate with the doors open. The indicator, used for centering the work piece, was attached to the indicator holder which was attached to the machine's spindle. He inadvertently activated the machine and it reached approximately 6000 to 6500 RPM, causing the indicator to disengage from the machine. The indicator flew out the open doors of the machine and struck Employee #1 in the shoulder. Employee #1 was hospitalized and received surgery for a deep laceration to his right shoulder.

Keywords: SHOULDER, LACERATION, STRUCK BY, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312667835 Hospitalized injury Cut/Laceration Numerical control machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.