Inspection Detail
Inspection: 312612757 - Roy Anderson Lumber Co., Inc.
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Roy Anderson Lumber Co., Inc.
1115 Columbia Ave
Tompkinsville, KY 42167
Mailing Address:
P O Box 275, Tompkinsville, KY 42167
Union Status: NonUnion
SIC:2421
NAICS: 321113/Sawmills
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/10/2009
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/07/2009
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102498524 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $10,500 | $0 | $0 | $0 | $0 | $10,500 |
Current Penalty | $10,500 | $0 | $0 | $0 | $0 | $10,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100147 C04 I | 06/19/2009 | 07/09/2009 | $3,500 | $3,500 | $0 | - | ||
2. | 01002 | Serious | 19100147 C06 I | 06/19/2009 | 07/09/2009 | $3,500 | $3,500 | $0 | - | ||
3. | 01003 | Serious | 19100147 C07 IA | 06/19/2009 | 07/09/2009 | $3,500 | $3,500 | $0 | - |
Investigation Summary
On January 14, 2009, Employee #1 and a coworker, a control operator, were performing maintenance work on a jump chain, while changing out an air valve. When Employee #1 signaled to the coworker to start the machine, his jacket was caught in a spinning shaft, pulling him into the machine. Employee #1 was killed. The safety procedures were not utilized.
Keywords: CHAIN, MAINTENANCE, CAUGHT BY, LOCKOUT, SHAFT, VALVE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 312612757 | Fatality | Other | Occupation not reported |