Powered by GoogleTranslate

Inspection Detail

Inspection: 312515463 - Emory Electric, Inc.

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 312515463
Report ID: 0453730
Date Opened: 08/27/2008

Site Address:
Emory Electric, Inc.
96 University Way - New Residence Hall Building B
Cullowhee, NC 28723

Mailing Address:
P O Box 3315, Asheville, NC 28802

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/26/2008

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/06/2009


Related Activity
Type Activity Nr Safety Health
Accident 102098217
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,200 $0 $0 $0 $0 $4,200
Current Penalty $3,780 $0 $0 $0 $0 $3,780
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260451 G01 11/26/2008 12/02/2008 $1,260 $1,400 $0 I - Informal Settlement  
2. 01001B Serious 19260454 A 11/26/2008 01/15/2009 $0 $0 $0 -  
3. 01002 Serious 19260452 N01 11/26/2008 12/02/2008 $1,260 $1,400 $0 I - Informal Settlement  
4. 01003A Serious 19260701 B 11/26/2008 12/02/2008 $1,260 $1,400 $0 I - Informal Settlement  
5. 01003B Serious 19260021 B02 11/26/2008 01/15/2009 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 202079661
Event: 08/26/2008
Employee Is Impaled on Rebar in Fall

On August 26, 2008, an employee and a coworker of an electrical subcontractor were cutting holes through a 16-in. thick, poured concrete wall with a core drill. They were working on a fabricated work platform comprised of wooden planking placed between two 12-ft, composite stepladders at a height of between 10.5-ft and 11-ft above the floor. The rig for the core drill was supported on a threaded bolt inserted in the wall above the drill site. When the third of four holes was completed, the employee loosened the nut on the support bolt to reposition the core drill. The nut came off of the bolt and base plate of the drill rig slid off the bolt. The weight of the drill and drill rig caused the employee to fall backwards off of the plank. The employee landed on a piece of exposed, uncapped, Number 6-gauge steel rebar protruding from the wall of a partially-constructed stair landing located adjacent to the work platform. The rebar entered the employee's left side below the arm pit, passed through the upper torso and exited his right side and right arm. The employee was hospitalized and treated for puncture wound.

Keywords: CHEST, REBAR, IMPALED, ELECTRICIAN, FALL, WORK SURFACE, PUNCTURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312515463 Hospitalized injury Puncture Electricians' apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.