Powered by GoogleTranslate

Inspection Detail

Inspection: 312459647 - Alstom Power Inc., Air Preheater Co.

Inspection Information - Office: Buffalo Area Office

 

Inspection Nr: 312459647
Report ID: 0213600
Date Opened: 08/27/2008

Site Address:
Alstom Power Inc., Air Preheater Co.
3020 Truax Road
Wellsville, NY 14895

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3443

NAICS: 332410/Power Boiler and Heat Exchanger Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/29/2008

Emphasis:

Case Closed: 11/18/2008


Related Activity
Type Activity Nr Safety Health
Accident 101331833

Investigation Summary

Investigation Nr: 201331055
Event: 08/26/2008
Employee Is Crushed and Is Killed

Employee #1 was crushed and killed. The nature of the event or injuries were not specified in the original narrative.

Keywords: CRUSHED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312459647 Fatality Other Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close