Inspection Detail
Inspection: 312432305 - Rock & Roll Pizza Inc.
Inspection Information - Office: Van Nuys District Office
Site Address:
Rock & Roll Pizza Inc.
6551 Topanga Cyn. Blvd.
Canoga Park, CA 91303
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5812
NAICS: 722110/Full-Service Restaurants
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/09/2009
Emphasis:
Case Closed: 07/21/2009
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102545860 | ||
Complaint | 207218314 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $170 | $0 | $170 |
Current Penalty | $0 | $0 | $0 | $170 | $0 | $170 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 6151 C01 | 07/09/2009 | 07/21/2009 | $85 | $85 | $0 | - | ||
2. | 01002 | Other | 6151 G02 | 07/09/2009 | 08/11/2009 | $85 | $85 | $0 | - |
Investigation Summary
On June 7, 2009, Employee #1, of Rock 'n Roll Pizza was trying to light the pilot light of a pizza oven. The oven contained gases inside the burner area; the gases ignited and caused a gas explosion within the burner area. No damage was done to the oven however, Employee #1 received second and third degree burns to his upper body. The Gas Company determined there was no safety valve to prevent the build up of gases within the burner chamber.
Keywords: BURN, CHEST, OVEN, FIRE, GAS, EXPLOSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 312432305 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |