Powered by GoogleTranslate

Inspection Detail

Inspection: 312431679 - Griff Industries, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 312431679
Report ID: 0950643
Date Opened: 05/13/2009

Site Address:
Griff Industries, Inc.
19761 Bahama St.
Northridge, CA 91324

Mailing Address:
19761 Bahama St., Northridge, CA 91324

Union Status: NonUnion

SIC:3089

NAICS: 326121/Unlaminated Plastics Profile Shape Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/15/2009

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/13/2009


Related Activity
Type Activity Nr Safety Health
Accident 102544772
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $740 $0 $740
Current Penalty $0 $0 $0 $740 $0 $740
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 461 A 06/03/2009 06/08/2009 $175 $175 $0 -  
2. 02001 Other 3203 B 10/06/2009 11/06/2009 $175 $175 $0 -  
3. 02002 Other 5194 E01 10/06/2009 11/06/2009 $195 $195 $0 -  
4. 02003 Other 3339 B 10/06/2009 10/09/2009 $195 $195 $0 -  

Investigation Summary

Investigation Nr: 202468021
Event: 03/27/2009
Employee Is Burned by Chemical

At 11:15 p.m. on March 27, 2009, Employee #1 was preparing to clean restrooms. To reach a container of bleach which was on top of a metal locker, she stood on a 5 gallon plastic pail that contained a floor stripper (Zep Industrial Purple Cleaner and Degreaser) with sodium hydroxide. Her right foot broke through the top of the pail and became immersed in the stripper. Employee #1 was directed by both a maintenance person and the crew leader to wash her foot, but she refused. She washed her foot later after arriving home. Employee #1 was subsequently hospitalized for treatment of the chemical burns. The floor stripping compound had not been used within the year prior to this incident.

Keywords: BURN, WORK RULES, CLEANING, UNSTABLE SURFACE, CHEMICAL BURN, CLEANING FLUID, WORK SURFACE, CHEMICAL, FOOT, UNSTABLE POSITION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312431679 Hospitalized injury Burn(Chemical) Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.