Inspection: 312317902 - Anthony International

Inspection Information - Office: High Hazard Unit - South

 

Inspection Nr: 312317902
Report ID: 0950662
Date Opened: 07/26/2010

Site Address:
Anthony International
12391 Montero Ave
Sylmar, CA 91342

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3442

NAICS: 332321/Metal Window and Door Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/04/2010

Planning Guide: Safety-Manufacturing

Emphasis: L:Arrastim, S:Targeted Compl & Consult

Case Closed: 02/16/2011


Related Activity
Type Activity Nr Safety Health
Accident 101694511
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $685 $0 $0 $0 $0 $685
Current Penalty $685 $0 $0 $0 $0 $685
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 4203 B 11/04/2010 11/11/2010 $505 $505 $0 -  
2. 02001 Serious 4207 A02 11/04/2010 11/11/2010 $180 $180 $0 -  

Investigation Summary

Investigation Nr: 101694511
Event: 07/21/2010
Employee Amputates Finger in Power Press Guard

At approximately 7:40 a.m. on July 21, 2010, Employee #1 was employed by the temporary employment agency Select Staffing Leasing and working at Anthony International, a manufacturer of freezer doors for the wholesale trade, in Sylmar, CA. Employee #1 was operating a punch press. He fed metal stock to the machine from his left-hand side through an opening in a guard. As Employee #1 fed the metal stock into the press, his right finger rested on the top surface of the metal stock, below the upper edge of the guard opening. When Employee #1 activated the punch press with his foot, the metal stock moved up, catching the index finger on Employee #1's right hand between the metal stock and the edge of the opening. His finger was crushed by the guard opening, and Employee #1 sustained an oblique amputation of the distal one-third of his right index finger. Employee #1 was transported to U.S. Health Works Medical Group in Encino, CA. The accident occurred because the size of the guard opening allowed Employee #1 to place his finger in the pinch point created by the guard and the stock. The injury was serious as defined by 330(h). The guard was inspected after the incident. The opening in the guard was one inch away from the point of operation. The height of the opening above the die was not provided in the report. The employer did, however, reduce the height of the opening above the die between the time of the accident and the time that inspectors arrived at the site.

Keywords: AMPUTATED, POWER PRESS, FINGER, GUARD, MACHINE OPERATOR, CATWALK, FOOT-POWERED PRESS, MECH MAT HANDLING, NIP POINT, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 312317902 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.