Inspection Detail
Inspection: 312296676 - Andersen Construction Company
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
Andersen Construction Company
6712 N Cutter Cir
Portland, OR 97217
Mailing Address:
Po Box 6712, Portland, OR 97228
Union Status: Union
SIC:1542
NAICS: 236220/Commercial and Institutional Building Construction
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/22/2008
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/27/2011
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260416 A03 | 10/13/2008 | 08/22/2008 | $0 | $1,500 | $0 | 10/17/2008 | D - Govt Dismissed | Citation has been deleted. |
Investigation Summary
A carpenter was working on the outside base wall of a new high-rise condominium. He was drilling holes in the ground to install reinforcement stakes for a wall form. His auger bit struck a buried 480-volt electrical conduit and penetrated the enclosed cable, creating an electrical fault. The ensuing electric arc burned the employee's right arm. He was hospitalized with second- and third-degree burns from the elbow to the fingertips of his right arm.
Keywords: BURN, ELECTRIC ARC, ELECTRICAL, E C, AUGER, ARM, ELECTRICAL FAULT, UNDRGRD POWER LINE, BLIND REACHING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 312296676 | Occupation not reported |