Inspection Detail
Inspection: 312195480 - The Austin Co,Dba Austin Electrical Enclosures
Inspection Information - Office: Nc Department Of Labor - Winston-Salem
Site Address:
The Austin Co,Dba Austin Electrical Enclosures
2100 Hoots Road
Yadkinville, NC 27055
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3644
NAICS: 335932/Noncurrent-Carrying Wiring Device Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/02/2009
Planning Guide: Health-Manufacturing
Emphasis: S:Program Improvement
Case Closed: 08/31/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100074020 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,225 | $0 | $0 | $0 | $0 | $1,225 |
| Current Penalty | $1,100 | $0 | $0 | $0 | $0 | $1,100 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100217 C01 I | 04/06/2009 | 04/09/2009 | $1,100 | $1,225 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100217 F02 | 04/06/2009 | 04/09/2009 | $0 | $0 | $0 | - |
Investigation Summary
On November 18, 2008, Employee #1's index, middle and ring fingers were amputated, when caught in a Wysong hydraulic shear.
Keywords: AMPUTATED, SHEAR, FINGER, CAUGHT BY, LACERATION, STRUCK BY
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 312195480 | Hospitalized injury | Amputation | Slicing and cutting machine operators |