Powered by GoogleTranslate

Inspection Detail

Inspection: 311957286 - Lucia, Llc

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 311957286
Report ID: 0626700
Date Opened: 06/19/2008

Site Address:
Lucia, Llc
6100 Main St, Gate 23
Houston, TX 77019

Mailing Address:
7904 N. Sam Houston Parkway W. Ste 100, Houston, TX 77064

Union Status: NonUnion

SIC:1741

NAICS: 238140/Masonry Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/08/2008

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/18/2009


Related Activity
Type Activity Nr Safety Health
Accident 101932994
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $7,000 $0 $7,000
Current Penalty $0 $0 $0 $4,480 $0 $4,480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260706 B 12/15/2008 01/05/2009 $4,480 $7,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201924453
Event: 06/19/2008
One Dead, Nine Injured Due to Wall Collapse in High Wind

On June 19, 2008, a crew of nine laborers, Employees #1 to #8 and a foreman, Employee #9, were high-lift grouting and washing unbraced concrete masonry unit, CMU, walls approximately 9 ft 8 in. in height, and varying in length from 15 ft 8 in. to 21 ft 8 in., on the second story of the McMurtry College dormitory under construction. A storm moved into the area, accompanied by a documented wind gust of approximately 68 miles per hour. The wind caused the unbraced first wall to collapse, striking the second wall. The second, third, fourth and fifth walls to collapse were struck by the preceding walls located 8 ft 4 in. south of the adjacent wall. The fifth wall was struck by the fourth, but collapsed into a double-bay room. Employee #1 was declared dead on site from blunt force injuries to the neck and torso. Employees #2 through #8 suffered injuries including fractures, sprains, strains and lacerations. Employees #2, #6 and #9 were hospitalized for their injuries, the others treated and released. Employee #9 suffered back injuries and multiple fractures. The employer utilized Standard Practice to determine the maximum unbraced height of the unsupported walls; however, the employer did not designate a responsible person to monitor wind conditions at the work, and did not remove employees from the work when winds exceeded speeds described in the Standard Practice for Bracing Masonry Walls under Construction, July 2001.

Keywords: FRACTURE, HIGH WIND, COLLAPSE, BACK, LACERATION, STRUCK BY, CONCRETE, SPRAIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311957286 Non Hospitalized injury Strain/Sprain Brickmasons and stonemasons apprentices
2 311957286 Non Hospitalized injury Cut/Laceration Brickmasons and stonemasons apprentices
3 311957286 Hospitalized injury Fracture Supervisors; brickmasons, stonemasons, tilesetters
4 311957286 Hospitalized injury Fracture Brickmasons and stonemasons apprentices
5 311957286 Non Hospitalized injury Strain/Sprain Brickmasons and stonemasons apprentices
6 311957286 Non Hospitalized injury Strain/Sprain Brickmasons and stonemasons apprentices
7 311957286 Non Hospitalized injury Strain/Sprain Brickmasons and stonemasons apprentices
8 311957286 Fatality Bruise/Contus/Abras Brickmasons and stonemasons apprentices
9 311957286 Hospitalized injury Fracture Brickmasons and stonemasons apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.