Powered by GoogleTranslate

Inspection Detail

Inspection: 311869432 - Doug & Judy Parker

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 311869432
Report ID: 0950621
Date Opened: 05/08/2009

Site Address:
Doug & Judy Parker
99w X Bowen Rd
Maxwell, CA 95987

Mailing Address:
4582 Freshwater Rd, Williams, CA 95987

Union Status: NonUnion

SIC:0761

NAICS: 115115/Farm Labor Contractors and Crew Leaders


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/07/2009

Planning Guide: Safety-Manufacturing

Emphasis: S:Agriculture (Aship)

Case Closed: 01/11/2013


Related Activity
Type Activity Nr Safety Health
Accident 102513561
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $13,500 $0 $0 $700 $0 $14,200
Current Penalty $10,850 $0 $0 $50 $0 $10,900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4650 C 10/13/2009 11/15/2009 $50 $350 $0 11/02/2009 F - Formal Settlement  
2. 01002 Other 4650 F 10/13/2009 11/15/2009 $0 $350 $0 11/02/2009 F - Formal Settlement  
3. 02001 Serious 4845 B 10/13/2009 10/16/2009 $10,850 $13,500 $0 11/02/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202489258
Event: 04/17/2009
Employee Receives Burns Using Cutting Torch

At approximately 9:00 a.m., on April 17, 2009, Employee #1 was servicing tractor discs at a jobsite location in Maxwell CA. To service a disc, he needed to remove a metal pin, which he did so with an oxygen and acetylene cutting torch. During his work, he switched from the cutting tip to the heating tip and the torch flashed back, catching the acetylene lead and his shirt sleeve on fire. He sustained burns to his arm and the right side of his ribcage. Employee #1 was transported to a medical center, where he underwent treatment and was hospitalized. From the investigation, it was found that the hose lines were new and in good condition but the torch did not have a spark arrestor (ie backflow device).

Keywords: BURN, ACETYLENE TORCH, ACETYLENE, MECHANIC, TRACTOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311869432 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close