Powered by GoogleTranslate

Inspection Detail

Inspection: 311718928 - Peacock Oil Company

Inspection Information - Office: Chicago North Area Office

 

Inspection Nr: 311718928
Report ID: 0524200
Date Opened: 01/28/2008

Site Address:
Peacock Oil Company
1060 E. Park Avenue
Libertyville, IL 60048

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5541

NAICS: 447110/Gasoline Stations with Convenience Stores


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/16/2008

Emphasis:

Case Closed: 01/14/2009


Related Activity
Type Activity Nr Safety Health
Accident 101263432
Referral 201268257 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $8,250 $0 $0 $0 $0 $8,250
Current Penalty $8,250 $0 $0 $0 $0 $8,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/17/2008 07/07/2008 $3,500 $3,500 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Serious 19100151 C 06/17/2008 09/01/2008 $1,250 $1,250 $0 I - Informal Settlement  
3. 01003A Serious 19101000 A02 06/17/2008 09/01/2008 $7,000 $3,500 $0 I - Informal Settlement  
4. 01003B Serious 19101000 E 06/17/2008 09/01/2008 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201262284
Event: 01/28/2008
Employee Dies of Carbon Monoxide Exposure

At approximately 9:40 p.m. on January 28, 2008, Employee #1, a maintenance worker with Peacock Oil Company, was called into work on this Sunday evening to repair some equipment. A worker found Employee #1 unresponsive in a 30 ft by 8 ft equipment room for the car wash operations. Two police officers removed Employee #1, who died of acute carbon monoxide poisoning. Acute cocaine intoxication was also revealed by the autopsy. Surveillance video footage showed that approximately 95 minutes had elapsed between the time Employee #1 entered the room and the time he was removed. The police reported that two open tool kits were on top of drums of car wash chemicals in the room. Apparently, Employee #1 had been working on the car wash equipment. Possible sources of the carbon monoxide in the equipment room included a defective boiler exhaust system, a lack of make-up air, and a defective heat exchanger on a room heating unit. The defective boiler (Raypak Model Number 724 WP-B, Serial Number 0988106022) had several cracks in the top, the side panels, and the draft hood. Initial carbon monoxide measurements made by the fire department indicated 0 ppm carbon monoxide in the room; however, this measurement was made after the room was ventilated. The gas company made a carbon monoxide measurement after the defective boiler was activated; this measurement showed approximately 1,100 ppm of carbon monoxide near one of the cracks. Employee #1's carboxyhemoglobin level was 42.7 after he arrived at the hospital. Based on that level, his exposure to carbon monoxide was calculated to be approximately 258 ppm as an 8-hour time-weighted average, which is 5.15 times the PEL of 50 ppm.

Keywords: REPAIR, HEATER, BOILER, EQUIPMENT FAILURE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311718928 Fatality Asphyxia Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close