Powered by GoogleTranslate

Inspection Detail

Inspection: 311587570 - Dustin Balch D/B/A Dmb Roofing

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 311587570
Report ID: 0111700
Date Opened: 12/29/2008

Site Address:
Dustin Balch D/B/A Dmb Roofing
Franklin Business Center - 20 Canal St.
Franklin, NH 03235

Mailing Address:
607 Province Road, Laconia, NH 03246

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/04/2009

Emphasis: L:Fall, S:Commercial Constr, S:Fall From Height

Case Closed: 09/09/2015


Related Activity
Type Activity Nr Safety Health
Referral 200619617 Yes
Referral 200619625 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 8
Current Violations 8 8
Initial Penalty $9,750 $0 $0 $0 $0 $9,750
Current Penalty $9,750 $0 $0 $0 $0 $9,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101200 E01 03/13/2009 04/15/2009 $1,500 $1,500 $0 04/09/2009 R - Review Commission  
2. 01001B Serious 19101200 G08 03/13/2009 03/26/2009 $0 $0 $0 04/09/2009 R - Review Commission  
3. 01001C Serious 19101200 H01 03/13/2009 04/15/2009 $0 $0 $0 04/09/2009 R - Review Commission  
4. 01002A Serious 19260020 B01 03/13/2009 04/15/2009 $750 $750 $0 04/09/2009 R - Review Commission  
5. 01002B Serious 19260021 B02 03/13/2009 04/15/2009 $0 $0 $0 04/09/2009 R - Review Commission  
6. 01003 Serious 19260034 A 03/13/2009 03/17/2009 $1,500 $1,500 $0 04/09/2009 R - Review Commission  
7. 01004 Serious 19260102 A01 03/13/2009 03/17/2009 $1,500 $1,500 $0 04/09/2009 R - Review Commission  
8. 01005 Serious 19260150 A01 03/13/2009 03/26/2009 $750 $750 $0 04/09/2009 R - Review Commission  
9. 01006A Serious 19260153 J 03/13/2009 03/18/2009 $750 $750 $0 04/09/2009 R - Review Commission  
10. 01006B Serious 19260153 L 03/13/2009 03/18/2009 $0 $0 $0 04/09/2009 R - Review Commission  
11. 01007 Serious 19260300 A 03/13/2009 03/17/2009 $1,500 $1,500 $0 04/09/2009 R - Review Commission  
12. 01008 Serious 19260501 B10 03/13/2009 03/17/2009 $1,500 $1,500 $0 04/09/2009 R - Review Commission  

Investigation Summary

Investigation Nr: 200613081
Event: 12/28/2008
Roofer Suffers Burns When Splashed by Hot Tar

On December 28, 2008, a roofer was using a tar kettle that was placed on the fire escape of the building he was working on. The lid to the kettle was open, and the worker was adding additional tar to it. The worker had not been adequately trained and was not aware that water was a problem if it got into the hot tar kettle. Water added to hot tar could result in a volcanic type eruption. The company was also unaware of the danger of water mixing with hot tar. It was raining lightly, and rain water started to run off the flat roof and into the open kettle. The tar splashed, burst into flame, and splattered. The worker stated that he was running the kettle at 500 degrees, according to the temperature gauge. Once the tar flashed over, it splattered onto the worker, who suffered second and third degree burns. The worker then jumped off the fire escape, since access to the interior of the building was blocked by the kettle. The worker ruptured three discs in his spine, as a result of the three story fall.

Keywords: SPINE, WORK RULES, FIRE ESCAPE, RUPTURE, ROOFER, FALL, HOT TAR, UNTRAINED, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311587570 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close