Inspection Detail
Inspection: 311570071 - Dcp Midstream
Inspection Information - Office: State Of New Mexico Environment Department Occupational Health & Safety Bureau
Site Address:
Dcp Midstream
N32.23028 W104.27273 Off Cr763
Carlsbad, NM 88220
Mailing Address:
370 17th Street, Suite 2500, Denver, CO 80202
Union Status: NonUnion
SIC:1389
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 12/12/2007
Emphasis: L:Oilgas
Case Closed: 07/28/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100042555 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $13,500 | $0 | $0 | $0 | $0 | $13,500 |
| Current Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 90005 A | 03/24/2008 | 04/10/2008 | $0 | $4,500 | $0 | 04/21/2008 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01002 | Serious | 90005 A | 03/24/2008 | 04/10/2008 | $4,500 | $4,500 | $0 | 04/21/2008 | F - Formal Settlement | |
| 3. | 01003A | Serious | 19100132 A | 03/24/2008 | 04/10/2008 | $0 | $4,500 | $0 | 04/21/2008 | F - Formal Settlement | Citation has been deleted. |
| 4. | 01003B | Serious | 19100132 D01 | 03/24/2008 | 04/10/2008 | $0 | $0 | $0 | A - Amendment | Citation has been deleted. | |
| 5. | 01003C | Serious | 19100132 F01 I | 03/24/2008 | 04/10/2008 | $0 | $0 | $0 | A - Amendment | Citation has been deleted. |
Investigation Summary
On November 14, 2007, Employee #1 was monitoring the liquid levels of a scrubber and fracture tanks on a gas pipeline site. He was on the receiving end of a pigging operation in process. Flammable gases vented from the tanks and ignited, when Employee #1 sparked a cigarette lighter. He was burned and died two weeks later in the hospital.
Keywords: BURN, VAPOR, CLEANING, FIRE, IGNITION SYSTEM, GAS, EXPLOSION, PIPE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311570071 | Fatality | Burn/Scald(Heat) | Occupation not reported |
Translate