Powered by GoogleTranslate

Inspection Detail

Inspection: 311493357 - Rayloc

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 311493357
Report ID: 0352450
Date Opened: 10/09/2007

Site Address:
Rayloc
100 Rayloc Drive
Hancock, MD 21750

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3714

NAICS: 336322/Other Motor Vehicle Electrical and Electronic Equipment Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/09/2007

Planning Guide: Safety-Manufacturing

Emphasis: S:Manufacturing(2000-3999)

Case Closed: 02/22/2008


Related Activity
Type Activity Nr Safety Health
Accident 102361326
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 3 9
Current Violations 6 3 9
Initial Penalty $17,200 $0 $0 $0 $0 $17,200
Current Penalty $7,740 $0 $0 $0 $0 $7,740
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 01/18/2008 01/19/2008 $1,350 $2,700 $0 I - Informal Settlement  
2. 01002 Serious 19100212 A03 II 01/18/2008 01/19/2008 $1,350 $2,700 $0 I - Informal Settlement  
3. 01003A Serious 19100213 C02 01/18/2008 01/19/2008 $1,350 $2,700 $0 I - Informal Settlement  
4. 01003B Serious 19100213 D01 01/18/2008 01/19/2008 $0 $0 $0 I - Informal Settlement  
5. 01004 Serious 19100219 D01 01/18/2008 01/19/2008 $1,350 $2,700 $0 I - Informal Settlement  
6. 01005 Serious 19100243 C04 01/18/2008 01/19/2008 $1,350 $2,700 $0 I - Informal Settlement  
7. 01006 Serious 5A0001 01/18/2008 01/19/2008 $990 $3,700 $0 I - Informal Settlement  
8. 02001 Other 19100132 A 01/18/2008 01/23/2008 $0 $0 $0 I - Informal Settlement  
9. 02002 Other 19100242 B 01/18/2008 01/19/2008 $0 $0 $0 I - Informal Settlement  
10. 02003 Other 19100305 G01 IV 01/18/2008 01/19/2008 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202496816
Event: 10/04/2007
Two Employees Sustain Burns in Flash Fire

On October 4, 2007, Employees #1 and #2 were filling a 33.5-gallon propane tank. The evening was humid and there was little to no air movement. The filling hose was connected to the tank. When the tank was full one employee attempted to shut the valve off and remove the hose. It would not turn off. The second went to the main tank and shut the emergency shut off valve. The tank kept leaking propane. Employee # 1 instructed Employee # 2 to move a forklift that was parked nearby. When he started the forklift, a flash fire occurred. According to the Fire Marshall, the propane tank was faulty and the valve inside the tank would not close, allowing the tank to leak out. Employee # 1 received second-degree and third-degree burns during the flash fire and was hospitalized. Employee # 2 received first-degree burns and was treated and released from the hospital the same day.

Keywords: BURN, FIRE, EQUIPMENT FAILURE, INDUSTRIAL TRUCK, VALVE, PROPANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311493357 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
2 311493357 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.