Powered by GoogleTranslate

Inspection Detail

Inspection: 311087365 - Robert C. Hatton, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 311087365
Report ID: 0418800
Date Opened: 11/28/2007

Site Address:
Robert C. Hatton, Inc.
374 Us Highway 27, North
South Bay, FL 33493

Mailing Address:
Po Box 220, Pahokee, FL 33476

Union Status: NonUnion

SIC:0191

NAICS: 111998/All Other Miscellaneous Crop Farming


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/28/2007

Emphasis:

Case Closed: 03/12/2008


Related Activity
Type Activity Nr Safety Health
Accident 100680206
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $18,200 $0 $0 $0 $0 $18,200
Current Penalty $14,450 $0 $0 $0 $0 $14,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100333 A01 02/28/2008 03/04/2008 $4,000 $4,900 $0 I - Informal Settlement  
2. 01002A Serious 19100333 B02 02/28/2008 04/15/2008 $4,000 $4,900 $0 I - Informal Settlement  
3. 01002B Serious 19100333 B02 I 02/28/2008 04/15/2008 $0 $0 $0 I - Informal Settlement  
4. 01003 Serious 19100178 L01 I 02/28/2008 03/04/2008 $1,450 $2,450 $0 I - Informal Settlement  
5. 01004 Serious 19100219 E03 I 02/28/2008 03/04/2008 $1,000 $1,050 $0 I - Informal Settlement  
6. 01005 Serious 19100305 B02 02/28/2008 03/04/2008 $4,000 $4,900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200677060
Event: 11/27/2007
Employee Is Electrocuted and Killed

At approximately 10:30 p.m. on November 27, 2007, Employee #1, a manager, was replacing a defective gearbox with a new "David Brown" gearbox (Model Number A16021208RN-13). In order to replace the gearbox, he had to remove the "Baldor Industrial" 208-230 volt electric motor, (Serial Number W0702052181). The motor supplied power to the "mule", a high horse powered gearbox with low rpm. He had asked a coworker in the vicinity of the start/stop station to turn the power on, so that he could test the gearbox. However, when he completed the task, he did not cover the junction box located underneath the electric motor because he was looking for a filler cap that was missing from the gearbox. From a crouched position, he went to stand up and started to lose his balance. He grabbed the eyebolt on top of the "mule" with his left hand and reached over with his right hand and grabbed the uncovered junction box that had exposed wires that were energized. He was electrocuted when he grabbed the eyebolt of the "mule". Employee #1 was killed. The employee had performed electrical work before, but he was not a certified electrician.

Keywords: ELECTROCUTED, LOST BALANCE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311087365 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.