Inspection Detail
Inspection: 311084396 - Jose Mendiata
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Jose Mendiata
1286 Nw 30th Street
Miami, FL 33142
Mailing Address:
18230 Nw 41st Court, Miami Gardens, FL 33055
Union Status: NonUnion
SIC:7623
NAICS: 811412/Appliance Repair and Maintenance
Inspection Type: Accident
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference:
Emphasis: S:Electrical
Case Closed: 10/26/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100679984 |
Investigation Summary
At approximately 1:00 p.m. On September 1, 2007, Employee #1 was installing a central air conditioner in the attic of an existing home. He contacted an energized circuit and was electrocuted.
Keywords: ATTIC, SHOCK, AIR CONDITIONER, ELECTROCUTED, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311084396 | Fatality | Electric Shock | Occupation not reported |