Inspection Detail
Inspection: 311082432 - Hayden Electric, Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Hayden Electric, Inc.
200 City Ln
Lauderhill, FL 33312
Mailing Address:
561 Sw 9 Terrace, Pompano, FL 33069
Union Status: NonUnion
SIC:1731
NAICS: 238210/Electrical Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/20/2007
Emphasis: L:Fall, S:Fall From Height
Case Closed: 01/08/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100679745 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $19,600 | $0 | $0 | $0 | $0 | $19,600 |
Current Penalty | $19,600 | $0 | $0 | $0 | $0 | $19,600 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 11/15/2007 | 11/28/2007 | $4,900 | $4,900 | $0 | - | ||
2. | 01002 | Serious | 19260020 B01 | 11/15/2007 | 11/28/2007 | $4,900 | $4,900 | $0 | - | ||
3. | 01003 | Serious | 19260453 B02 V | 11/15/2007 | 11/28/2007 | $4,900 | $4,900 | $0 | - | ||
4. | 01004 | Serious | 19260454 A | 11/15/2007 | 11/28/2007 | $4,900 | $4,900 | $0 | - |
Investigation Summary
At approximately 1:15 p.m. on June 19, 2007, Employee #1 and a coworker were using an aerial lift truck to remove a 15 ft tall cast iron street lamp from the ground. The lamp post was in a grassy area on the sidewalk and the coworker had dug around the base to loosen it. Employee #1 then placed a nylon sling with a slip knot around the neck of the post. He was starting to lift the post out of the ground when the sling slid off the top of the post and the bucket bounced. Employee #1 was ejected from the basketand fell approximately 15 ft to the ground. He suffered severe head trauma and was placed on life support at the hospital. Employee #1 died the following day.
Keywords: EJECTED, HEAD, UNSECURED, WORK RULES, CONSTRUCTION, FALL, FALL PROTECTION, MECH MAT HANDLING, AERIAL LIFT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 311082432 | Fatality | Concussion | Occupation not reported |