Inspection: 311071930 - Key Energy Services, Inc.

Inspection Information - Office: High Hazard Unit - Central

 

Inspection Nr: 311071930
Report ID: 0950663
Date Opened: 02/05/2009

Site Address:
Key Energy Services, Inc.
Chevron Lease Orradre Well #J13-A
San Ardo, CA 93450

Mailing Address:
5080 Caifornia Aveue, Suite 150, Bakersfield, CA 93309

Union Status: NonUnion

SIC:1381

NAICS: 213111/Drilling Oil and Gas Wells


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/28/2009

Emphasis:

Case Closed: 03/01/2012


Related Activity
Type Activity Nr Safety Health
Accident 101488765
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $0 $0 $0 $5,600 $0 $5,600
Current Penalty $0 $0 $0 $300 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 05/28/2009 06/30/2009 $0 $5,000 $0 06/18/2009 D - Govt Dismissed Citation has been deleted.
2. 01002 Other 14001 B 05/28/2009 06/30/2009 $0 $300 $0 06/18/2009 D - Govt Dismissed Citation has been deleted.
3. 01003 Other 14300040 A 05/28/2009 06/30/2009 $300 $300 $0 06/18/2009 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202506820
Event: 01/21/2009
Oil and Gas Worker Strikes Head Against Pipes and Later Dies

At approximately 2:15 p.m. on January 21, 2009, Employee #1 was removing 3.5 inch tubing and the 8.75 inch scraper out of a hole that was just drilled. Employee #1 went up to the work platform. At about the time the 21st section of tubing was pulled out of the hole, the floor hands witnessed heavy oil coming out of the casing valve and informed the operator. The slips began to float up because of the heavy oil on the outside of the tubing. The slips normally rest on 14 inch rubber stripping with a 2.875 inch hole opening, on top of a Blow Out Preventer (BOP). As the tubing was being pulled up, the slips impacted the underside of the work platform at a right angle. The second collar came out of the BOP, and the actuating arm of the collar struck the underside of the work platform, causing the pipes to bend. The upward force caused Employee #1 to lost his balance, throwing his head against the tubing or the tubing tongs above the platform. Employee #1 then collapsed onto the work platform, and witnesses contacted EMS. An ambulance responded and took Employee #1 to the San Ardo Oil Field helipad, where he was airlifted to Community Regional Medical Center and later died on February 4, 2009.

Keywords: HEAD, OIL WELL DRILLING, STRUCK AGAINST, PIPE, STRUCK BY, TONGS, LOST BALANCE, WORK PLATFORM, OIL RIG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311071930 Fatality Concussion Drillers, oil well
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.