Inspection Detail
Inspection: 311018733 - Silver State Wire Rope And Rigging, Inc.
Inspection Information - Office: Nv-E-Las Vegas 0953220
Site Address:
Silver State Wire Rope And Rigging, Inc.
3853 Losee Road
North Las Vegas, NV 89030
Mailing Address:
5380 Valley View, Suite A, Las Vegas, NV 89118
Union Status: NonUnion
SIC:2298
NAICS: 314991/ Rope, Cordage, and Twine Mills
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 08/15/2007
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/06/2008
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101044592 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | ||||||
Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100132 D01 | 08/27/2007 | 09/29/2007 | $0 | $1,500 | $0 | 09/18/2007 | R - Review Commission | Citation has been deleted. |
2. | 01002A | Serious | 19100333 A | 08/27/2007 | 09/29/2007 | $0 | $1,500 | $0 | 09/18/2007 | R - Review Commission | Citation has been deleted. |
3. | 01002B | Serious | 19100333 C02 | 08/27/2007 | 09/29/2007 | $0 | $0 | $0 | R - Review Commission | Citation has been deleted. |
Investigation Summary
Two employees were on the catwalk of a 23-metric ton, top-running, double-girder overhead bridge crane made by DEMAG (Serial Number 94156). They were repairing a radio transmitter-receiver for the crane's remote control system (Remtron Model Number 25S11A). One employee was sitting in front of the crane's bridge control cabinet, tracing and testing the function of conductors for the crane. The second employee was in front of the crane's hoist control cabinet. The employee checking the wiring was sweating profusely from the heat as he worked in the energized 480-volt cabinet. He grabbed a 120-volt conductor with needlenose pliers. A portion of the plastic coating on the handle of the pliers was missing, and the employee was electrocuted. The second employee received an electric shock when he removed the first employee from the circuit. The first employee was pronounced dead at the North Vista Hospital. (The employee who received an electric shock was not listed on an injury line on the original form.)
Keywords: OVERHEAD CRANE, ELECTRIC SHOCK, ELECTRICAL CABINET, HAND TOOL, E GI II, ELEC PROTECT EQUIP, ELECTROCUTED, HIGH TEMPERATURE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 311018733 | Fatality | Electric Shock | Electricians |