Powered by GoogleTranslate

Inspection Detail

Inspection: 311015986 - Legacy Electric, Inc.

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 311015986
Report ID: 0953220
Date Opened: 06/18/2007

Site Address:
Legacy Electric, Inc.
1999 Whitney Mesa, Suite E
Henderson, NV 89014

Mailing Address:
6672 Boulder Highway, Suite 7, Las Vegas, NV 89122

Union Status: NonUnion

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 06/28/2007

Planning Guide: Safety-Construction

Emphasis: L:Elut, S:Construction

Case Closed: 08/08/2007


Related Activity
Type Activity Nr Safety Health
Accident 101044485
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $2,500 $0 $0 $0 $0 $2,500
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19261053 B22 07/02/2007 07/07/2007 $1,500 $2,500 $0 I - Informal Settlement  
2. 01001B Serious 19261060 A 07/02/2007 07/20/2007 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201043114
Event: 06/18/2007
Employee injured in fall from ladder, later dies

On June 18, 2007, Employee #1, an apprentice electrician, and coworkers were running string through conduit for phone lines as part of a renovation on a single-story professional building in Henderson, NV. Employee #1 had just finished tying string on the ends of five or six runs of fish tape that a coworker was feeding and pushing through the other end of the conduit. Employee #1 then proceeded to feed and push fish tape through the opening of an electrical box where the conduit for the phone lines terminated. He was using a Husky 12 ft portable trestle ladder, model 01-41200-00, with a maximum standing level of 9 ft 5-3/4 in., to access the electrical box, which was located on the wall about 16 ft from the ground. Coworkers heard Employee #1 scream and one turned in time to see him and the ladder fall. Employee #1's back and head struck the concrete floor as he landed and he suffered a closed head fracture and a subdural hemotoma. He was transported by Emergency Services to Sunrise Hospital, where he was placed on life support until he died at 8:37 p.m. on June 19, 2007.

Keywords: FRACTURE, HEAD, WORK RULES, LADDER, CONSTRUCTION, FALL, FALL PROTECTION, UNSTABLE POSITION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 311015986 Fatality Bruise/Contus/Abras Electricians' apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.