Inspection Detail
Inspection: 310956834 - Reynolds, Inc.
Inspection Information - Office: Atlanta West Area Office
Site Address:
Reynolds, Inc.
173 Boulevard Se
Atlanta, GA 30316
Mailing Address:
121 Roberts Street, Fairburn, GA 30213
Union Status: NonUnion
SIC:1794
NAICS: 238910/Site Preparation Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 12/06/2007
Planning Guide: Safety-Construction
Emphasis: L:Ohpwrlne
Case Closed: 03/23/2009
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100202779 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
| Current Penalty | $0 | $0 | $0 | $3,150 | $0 | $3,150 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19260416 A01 | 04/16/2008 | 04/28/2008 | $3,150 | $6,300 | $0 | 05/07/2008 | J - ALJ Decision |
Investigation Summary
On November 19, 2007, Employee #1, a supervisor, was raising a light tower to provide illumination for coworkers in a trench when he contacted the energized, 11,400-volt power lines. An explosion ensued and he was electrocuted.
Keywords: CLEARANCE, OVERHEAD POWER LINE, ELECTRICAL, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELEC CIRC PART--MISC, ELECTRICAL FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310956834 | Fatality | Electric Shock | Occupation not reported |
Translate