Inspection Detail
Inspection: 310928841 - Mike Bailey Dba Jan-Pro Cleaning Systems Of Raleig
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Mike Bailey Dba Jan-Pro Cleaning Systems Of Raleig
2131 Harrod Street
Raleigh, NC 27604
Mailing Address:
190 Tomahawk Drive, Clayton, NC 27520
Union Status: NonUnion
SIC:7349
NAICS: 561720/Janitorial Services
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/16/2007
Planning Guide: Health-Manufacturing
Emphasis: S:Program Improvements
Case Closed: 04/09/2008
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100358670 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,400 | $0 | $0 | $0 | $0 | $1,400 |
| Current Penalty | $700 | $0 | $0 | $0 | $0 | $700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 7F010104 A IV | 11/20/2007 | 11/26/2007 | $700 | $1,400 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19101000 E | 11/20/2007 | 11/26/2007 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01001C | Serious | 19101200 E01 | 11/20/2007 | 01/09/2008 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 01001D | Serious | 19101200 G01 | 11/20/2007 | 01/09/2008 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 01001E | Serious | 19101200 H01 | 11/20/2007 | 01/09/2008 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
The owner and Employee #1 were cleaning and buffing a tile floor with a propane-powered buffing machine. The main section of the facility was 30-ft by 12-ft. There was also an office, which was 8-ft by 11-ft. The ceiling height was 8 ft and 8-in. The owner and Employee #1 were found laying on the floor, unconscious, by a coworker. The coworker and his son summoned emergency medical services and pulled the owner and Employee #1 out of the facility. Fire department personnel responded and entered the building after it was ventilated for a short time and obtained carbon monoxide levels of 1,000 ppm. The owner and Employee #1 were transported to the hospital by EMS. Hospital records indicated that they suffered from carbon monoxide poisoning. Employee #1's blood was drawn approximately 30 minutes after leaving the scene and after having 100 oxygen administered. His carboxyhemoglobin level was found to be 41. The owner and Employee #1 were transported to another hospital for hyperbaric oxygen therapy. After being released, the employer had the emissions from the buffer tested and testing indicated carbon monoxide levels greater than 2,000 ppm.
Keywords: LUNG, UNCONSCIOUSNESS, ASPHYXIATED, INHALATION, HAND TOOL, CARBON MONOXIDE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310928841 | Hospitalized injury | Asphyxia | Janitors and cleaners | ||
| 2 | 310928841 | Hospitalized injury | Asphyxia | Janitors and cleaners |