Inspection Detail
Inspection: 310922778 - Nc State University
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Nc State University
2700 Stension Dr.
Raleigh, NC 27695
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:8221
NAICS: 611310/ Colleges, Universities, and Professional Schools
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/05/2007
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/18/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100358365 | ||
Referral | 202642138 | Yes |
Investigation Summary
At approximately 3:00 p.m. on March 27, 2010, an employee was checking on the fluid flow computer and meter device used to monitor the flow in a 0.75 inch pipe when its exposed battery exploded. The employee following the incorrect instructions, previously opened the unit and connected a 15 VDC transformer device originally used to power commuters' speakers by cutting its wires and wrapping them around the power wires for the unit. The employee did not finish the task leaving the back cast aluminum cover off. The power applied in turn back fed the 3 VDC lithium "D" size battery, causing it to heat and then explode. The employee received burns on the head but was not hospitalized. The explosion caused release of sulfur gas that resulted in the evacuation of the 6-story building.
Keywords: BATTERY, BURN, HEAD, EXPLOSION, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310922778 | Non Hospitalized injury | Burn(Chemical) | Occupation not reported |