Inspection Detail
Inspection: 310829080 - Conner'S Mfg, Inc
Inspection Information - Office: Fresno District Office
Site Address:
Conner'S Mfg, Inc
3731 West Franklin
Fresno, CA 93706
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3499
NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/17/2009
Emphasis:
Case Closed: 01/17/2009
Investigation Summary
On January 16, 2009, the owner of Conner's Manufacturing, Inc., was killed when an air tank exploded.
Keywords: COMPRESSED AIR, EXPLOSION, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310829080 | Fatality | Other | Specified mechanics and repairers |