Powered by GoogleTranslate

Inspection Detail

Inspection: 310825849 - Key Energy Services

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 310825849
Report ID: 0950625
Date Opened: 05/30/2008

Site Address:
Key Energy Services
W Palmer Ave & Derrick Ave
Coalinga, CA 93210

Mailing Address:
5080 California Ave # 150, Bakersfield, CA 93309

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/2008

Emphasis:

Case Closed: 03/04/2013


Related Activity
Type Activity Nr Safety Health
Accident 362052326
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 4 11
Current Violations 2 2
Initial Penalty $48,365 $0 $0 $1,305 $0 $49,670
Current Penalty $42,000 $0 $0 $0 $0 $42,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 09/29/2008 11/03/2012 $0 $185 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
2. 01002 Other 3203 A02 09/29/2008 11/01/2008 $0 $375 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
3. 01003 Other 3203 A05 09/29/2008 11/01/2008 $0 $185 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
4. 01004 Other 5192 Q01 09/29/2008 11/03/2008 $0 $560 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
5. 02001 Serious 3203 A04 09/29/2008 11/01/2008 $0 $6,750 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
6. 03001 Serious 3203 A07 09/29/2008 11/01/2008 $0 $6,750 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
7. 04001 Serious 6507 09/29/2008 11/03/2008 $17,000 $6,750 $0 10/21/2008 F - Formal Settlement  
8. 05001 Serious 5192 Q03 A 09/29/2008 11/03/2008 $0 $8,435 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
9. 06001 Serious 5192 Q06 C 09/29/2008 11/01/2008 $0 $840 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
10. 07001 Serious 5192 Q06 E 09/29/2008 11/01/2008 $0 $840 $0 10/21/2008 F - Formal Settlement Citation has been deleted.
11. 08001 Serious 6513 A 09/29/2008 11/01/2012 $25,000 $18,000 $0 10/21/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201491164
Event: 03/31/2008
Employee Is Burned While Servicing Steam Injection Well

On March 31, 2008, Employee #1 and two coworkers were replacing a failed packer on an AHERA Energy steam injection well, which measured 450-feet deep. The crew isolated the well from its steam source and injected the well with one hundred barrels of brine water that was pumped down the injection string. Then the wellhead was removed and the blowout prevention equipment (BOPE) was lowered into place by way of a mobile derrick. The BOPE rested on a block, which together weighed 6,000 pounds. Despite the heaviness of the BOPE and block combination, the well's injection string rose up and became fouled in the mobile derrick's block. This raised concern because it raised the potential for a well blowout (estimated sound level >130 dB). Employee #1 and his coworkers notified their supervisor and began pumping the well casing with brine water in an attempt to settle the well. After the injection string fell, allowing the BOPE to contact the well, Employee #1 and his coworkers were instructed to bolt up the BOPE. While the supervisor was operating the derrick, Employee #1 and his coworkers worked to bolt the BOPE into place. As Employee #1 was in a crouched position, a backflow of hot fluid came from the injection string and contacted him. The crew immediately responded using set emergency procedures. Employee #1 was taken to Fresno Community Hospital, where he was hospitalized and treated in their burn unit for first- and second-degree burns to his shoulder and back. The accident investigation revealed that Employee #1 was not wearing the appropriate protective equipment.

Keywords: BURN, PPE, WELL, EQUIPMENT FAILURE, STEAM, STRUCK BY, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310825849 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.