Inspection Detail
Inspection: 310824891 - P G & E
Inspection Information - Office: Fresno District Office
Site Address:
P G & E
4319 W Princeton Ave
Fresno, CA 93722
Mailing Address:
7205 National Drive, Livermore, CA 94550
Union Status: Union
SIC:4939
NAICS: 221121/Electric Bulk Power Transmission and Control
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/19/2008
Emphasis:
Case Closed: 10/06/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362054579 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 4 | 9 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $37,120 | $0 | $0 | $7,870 | $0 | $44,990 |
Current Penalty | $6,750 | $0 | $0 | $420 | $0 | $7,170 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 1509 B | 05/19/2008 | 06/24/2008 | $420 | $420 | $0 | 06/06/2008 | F - Formal Settlement | |
2. | 01002 | Other | 1510 C | 05/19/2008 | 06/24/2008 | $0 | $420 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
3. | 01003 | Other | 1541 G01 C | 05/19/2008 | 06/24/2008 | $0 | $280 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
4. | 02001 | Other | 1510 B | 05/19/2008 | 06/24/2008 | $0 | $6,750 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
5. | 03001 | Serious | 1511 A | 05/19/2008 | 06/24/2008 | $0 | $6,750 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
6. | 04001 | Serious | 1514 A | 05/19/2008 | 06/24/2008 | $0 | $6,750 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
7. | 05001 | Serious | 3203 A07 D | 05/19/2008 | 06/24/2008 | $6,750 | $6,750 | $0 | 06/06/2008 | F - Formal Settlement | |
8. | 06001 | Serious | 3328 A | 05/19/2008 | 06/24/2008 | $0 | $8,435 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
9. | 07001 | Serious | 5416 C | 05/19/2008 | 06/24/2008 | $0 | $8,435 | $0 | 06/06/2008 | D - Govt Dismissed | Citation has been deleted. |
Investigation Summary
On November 20, 2007, Employee #1, an equipment operator, was repairing a natural gas line leak in Fresno, California. Employee #1 was replacing a section of class Number 3 residential polypropylene plastic service line, which had 1 in. in diameter and 0.090-in. wall thickness. The gas line was damaged by an electrical crew, while removing tree roots to access the electrical conductors in a joint service trench. The gas line was damaged with a shovel causing a blowing gas leak. The gas line had pressure of 50 PSI and was covered with dirt to muffle the noise. A gas crew, together with Employee #1 and a gas construction foreman, were dispatched to repair the leak. An attempt was made to enlarge the excavation with a backhoe, but the roots caused the ground to rise as a unit. To mitigate further property damage the crew decided to cut away the roots using a saw. An attempt was made with a hand saw, but progress was slow, thus the crew decided to use a Bosch 18 volt cordless reciprocation saw. Employee #1 got into the excavation for positioning and energizing the saw, which ignited the flammable gas. Employee #1 got out from the excavation with only a flash burn to his face and irregular heart beat. He was hospitalized with nonserious injuries to his face and heart condition, which was determined as nonoccupational. Both, Employee #1 and the gas construction foreman were not aware that a cordless power tool would be an ignition source. Root cause for this event was the use of a spark producing power tool, which was an ignition source, in a flammable atmosphere.
Keywords: BURN, EXCAVATION, REPAIR, FIRE, IGNITION SYSTEM, GAS, SAW, GAS LEAK, FACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310824891 | Hospitalized injury | Burn/Scald(Heat) | Specified mechanics and repairers |