Inspection Detail
Inspection: 310820147 - Airtech Services
Inspection Information - Office: Fresno District Office
Site Address:
Airtech Services
1993 Belmont Avenue
Mendota, CA 93640
Mailing Address:
5466 E Lamona Ave Ste 101, Fresno, CA 93727
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/19/2007
Emphasis: S:Construction (Cship)
Case Closed: 10/27/2009
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362053571 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $16,650 | $0 | $0 | $335 | $0 | $16,985 |
Current Penalty | $0 | $0 | $0 | $785 | $0 | $785 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A | 11/20/2007 | 12/03/2007 | $335 | $335 | $0 | 12/12/2007 | F - Formal Settlement | |
2. | 02001 | Serious | 3314 G | 11/20/2007 | 11/26/2007 | $0 | $4,050 | $0 | 12/12/2007 | F - Formal Settlement | Citation has been deleted. |
3. | 03001 | Other | 23200004 A | 11/20/2007 | 11/26/2007 | $450 | $12,600 | $0 | 12/12/2007 | F - Formal Settlement |
Investigation Summary
At 3:00 p.m. on May 15, 2007, Employee #1, of Airtech Services, was servicing a 480 volt Groen steamer oven in the kitchen of the Mendota Unified School District's high school campus. He was stretched out on two smaller appliances next to the oven, and was reaching behind it with his right arm to reconnect the water supply when his head contacted the exposed electrical terminals on the oven. Employee #1 was electrocuted. The Fresno County Coroner's Office and Sheriff's Department responded to a call by the School District's office.
Keywords: HEAD, ELECTRICAL, OVEN, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELEC CIRC PART--MISC, BLIND REACHING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310820147 | Fatality | Electric Shock | Supervisors; electricians & power transm. install. |