Powered by GoogleTranslate

Inspection Detail

Inspection: 310731989 - Elco Steel

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 310731989
Report ID: 0522000
Date Opened: 02/26/2007

Site Address:
Elco Steel
738 N. Main St.
Springboro, OH 45066

Mailing Address:
1517 River Rd., Dayton, OH 45418

Union Status: Union

SIC:1791

NAICS: 238120/Structural Steel and Precast Concrete Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/27/2007

Emphasis: L:Fall, L:Piv, S:Commercial Constr, S:Fall From Height, S:Powered Ind Vehicle

Case Closed: 06/19/2007


Related Activity
Type Activity Nr Safety Health
Referral 201954757 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $2,500 $0 $0 $0 $0 $2,500
Current Penalty $900 $0 $0 $0 $0 $900
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260453 B02 I 03/21/2007 03/27/2007 $900 $2,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201954963
Event: 02/26/2007
Employee Is Caught Between Equipment and Structure, Injured

Employee #1, a Steelworker, was engaged in open web bar joist installation at a height of approximately 14 ft. Employee #1 was maneuvering an articulating boom lift (aerial lift) into position under the bar joist. The aerial lift had a malfunction in the travel lever (forward and reverse). It was previously noted that the lever has had a tendencies to not fully return to neutral position once the lever was release. The safety device on this lever was broken prior to the accident. Employee #1 traveled forward released that lever, then immediately started booming up between bar joist not knowing that aerial lift was still traveling slightly. Employee #1 was caught between a bar joist and the equipment platform. Employee #1 was unable to reach the controls to shut down the aerial lift. Nearby coworkers stopped the aerial lift utilizing ground control and lowered Employee #1 to the ground. Employee #1 suffered minor injuries to the chest, shoulders, and back. Employee #1 was treated at the hospital and released that evening.

Keywords: PLATFORM, JOIST, EQUIPMENT FAILURE, CAUGHT BETWEEN, ABRASION, AERIAL LIFT, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310731989 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close