Powered by GoogleTranslate

Inspection Detail

Inspection: 310715214 - Service Specialists, Inc.

Inspection Information - Office: Osha Philadelphia Area Office

 

Inspection Nr: 310715214
Report ID: 0317000
Date Opened: 03/13/2007

Site Address:
Service Specialists, Inc.
Friendly'S Restaurant #776; 11291 Roosevelt Blvd.
Philadelphia, PA 19154

Mailing Address:
101 Chestnut Street, Williamstown, NJ 08094

Union Status: NonUnion

SIC:7623

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/19/2007

Emphasis:

Case Closed: 06/29/2007


Related Activity
Type Activity Nr Safety Health
Accident 102021912
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 2 2 4
Initial Penalty $2,100 $0 $0 $0 $0 $2,100
Current Penalty $1,365 $0 $0 $0 $0 $1,365
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100101 B 06/04/2007 06/17/2007 $683 $1,500 $0 I - Informal Settlement  
2. 01002A Serious 19101200 E01 06/04/2007 06/17/2007 $682 $600 $0 I - Informal Settlement  
3. 01002B Serious 19101200 G01 06/04/2007 06/17/2007 $0 $0 $0 I - Informal Settlement  
4. 01002C Serious 19101200 H01 06/04/2007 06/17/2007 $0 $0 $0 I - Informal Settlement  
5. 02001 Other 19100132 D02 06/04/2007 06/17/2007 $0 $0 $0 I - Informal Settlement  
6. 02002 Other 19100132 F01 I 06/04/2007 06/17/2007 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202004925
Event: 03/13/2007
Employee Is Killed When Refrigeration System Explodes

On March 13, 2007, Employee #1 was working for a firm that, as a subcontractor, performed maintenance on commercial food service equipment. He was in the kitchen area of a single-story restaurant, attempting to locate the source of a refrigerant leak in an ice cream storage dipping cabinet. Employee #1 connected a cylinder containing pressurized nitrogen to the dipping cabinet's refrigeration system via a hose without using a pressure reducing device, such as a pressure regulator or pressure relief valve. The cylinder's internal pressure of approximately 2,200 psig was considerably in excess of the dipping cabinet's maximum test pressure of approximately 150 psig. This disparity overpressurized the dipping cabinet's refrigeration system and caused it to explode. The upper part of the compressor broke off and struck Employee #1 in the head, killing him.

Keywords: HEAD, MAINTENANCE, NITROGEN, REFRIGERANT, EXPLOSION, HIGH PRESSURE, STRUCK BY, REFRIGERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310715214 Fatality Cut/Laceration Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close