Powered by GoogleTranslate

Inspection Detail

Inspection: 310619580 - Baxter Healthcare Corporation - North Cove Plant

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 310619580
Report ID: 0453730
Date Opened: 11/17/2006

Site Address:
Baxter Healthcare Corporation - North Cove Plant
Highway 221 N & Pitts Station Road
Marion, NC 28752

Mailing Address:
Po Box 1390, Marion, NC 28752

Union Status: NonUnion

SIC:2834

NAICS: 325412/Pharmaceutical Preparation Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/20/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/27/2006


Related Activity
Type Activity Nr Safety Health
Accident 102096641

Investigation Summary

Investigation Nr: 202077764
Event: 11/16/2006
Employee Is Injured While Clearing Jam

On November 16, 2006, Employee #1 was operating a multi-up printing machine and was attempting to clear a jam. She was injured when the machine began its indexing function and pinned her left arm. She was hospitalized at Mission Hospital, in Asheville, NC, for multiple fractures below the elbow.

Keywords: FRACTURE, PRINTING PRESS, PRINTING, MACHINE OPERATOR, JAMMED, ARM, MACHINE--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310619580 Hospitalized injury Fracture Miscellaneous printing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.