Powered by GoogleTranslate

Inspection Detail

Inspection: 310602578 - Olympic Air Conditioning Inc

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 310602578
Report ID: 0950633
Date Opened: 04/30/2008

Site Address:
Olympic Air Conditioning Inc
2600 Grand Avenue
Chino Hills, CA 91710

Mailing Address:
12106 Park Street, Cerritos, CA 90703

Union Status: NonUnion

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/14/2008

Emphasis:

Case Closed: 02/05/2019


Related Activity
Type Activity Nr Safety Health
Accident 102551686
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $10,800 $0 $0 $260 $0 $11,060
Current Penalty $4,000 $0 $0 $260 $0 $4,260
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 10/16/2008 11/18/2008 $260 $260 $0 11/07/2008 F - Formal Settlement  
2. 02001 Serious 1632 B03 10/16/2008 10/29/2008 $4,000 $10,800 $0 11/07/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202448080
Event: 04/30/2008
Employee Is Killed in Fall Through Floor Opening

At approximately 9:00 a.m. on April 30, 2008, Employee #1, a superintendent of ER1 at the jobsite, was working on the second floor of a church construction site in Chino Hills, California. He stepped on a temporary floor cover of one of the floor openings and fell 19 ft 3 in. to the concrete floor. Employee #1 sustained a fatal multiple blunt force trauma. A Medical Engine Number 66 from the Chino Valley Fire Department arrived on scene and provided emergency aid to Employee #1. The ambulance arrived at the scene and transported Employee #1 to the Chino Valley Medical Center, where he was pronounced dead minutes later. The floor opening was 44.5-in. by 48 in. and was designed for vents and ducts of a heating, ventilating and air conditioning system plan. The floor cover was made of two pieces of plywood, approximately 43.875-in. by 24-in. by 0.75-in., butted together and fastened into the 2 by 4 wood support. The 2 by 4s were fastened into the metal closure plate using three 2-in. Tec screws on each of four sides of the hole. A smaller piece of plywood, 8.875-in. by 24-in. by 0.75-in. joined the two pieces of plywood together on top center.

Keywords: HEAD, COVER, VENTILATION, BUILDING, CLEANING, CONSTRUCTION, FALL, FLOOR OPENING, CONCRETE, WORK SURFACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310602578 Fatality Other Supervisors, cleaning and building service workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.