Inspection Detail
Inspection: 310602578 - Olympic Air Conditioning Inc
Inspection Information - Office: San Bernardino District Office
Site Address:
Olympic Air Conditioning Inc
2600 Grand Avenue
Chino Hills, CA 91710
Mailing Address:
12106 Park Street, Cerritos, CA 90703
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/14/2008
Emphasis:
Case Closed: 02/05/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102551686 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $10,800 | $0 | $0 | $260 | $0 | $11,060 |
Current Penalty | $4,000 | $0 | $0 | $260 | $0 | $4,260 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 1509 A | 10/16/2008 | 11/18/2008 | $260 | $260 | $0 | 11/07/2008 | F - Formal Settlement | |
2. | 02001 | Serious | 1632 B03 | 10/16/2008 | 10/29/2008 | $4,000 | $10,800 | $0 | 11/07/2008 | F - Formal Settlement |
Investigation Summary
At approximately 9:00 a.m. on April 30, 2008, Employee #1, a superintendent of ER1 at the jobsite, was working on the second floor of a church construction site in Chino Hills, California. He stepped on a temporary floor cover of one of the floor openings and fell 19 ft 3 in. to the concrete floor. Employee #1 sustained a fatal multiple blunt force trauma. A Medical Engine Number 66 from the Chino Valley Fire Department arrived on scene and provided emergency aid to Employee #1. The ambulance arrived at the scene and transported Employee #1 to the Chino Valley Medical Center, where he was pronounced dead minutes later. The floor opening was 44.5-in. by 48 in. and was designed for vents and ducts of a heating, ventilating and air conditioning system plan. The floor cover was made of two pieces of plywood, approximately 43.875-in. by 24-in. by 0.75-in., butted together and fastened into the 2 by 4 wood support. The 2 by 4s were fastened into the metal closure plate using three 2-in. Tec screws on each of four sides of the hole. A smaller piece of plywood, 8.875-in. by 24-in. by 0.75-in. joined the two pieces of plywood together on top center.
Keywords: HEAD, COVER, VENTILATION, BUILDING, CLEANING, CONSTRUCTION, FALL, FLOOR OPENING, CONCRETE, WORK SURFACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 310602578 | Fatality | Other | Supervisors, cleaning and building service workers |