Powered by GoogleTranslate

Inspection Detail

Inspection: 310602487 - Hill Crane Service Inc.

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 310602487
Report ID: 0950633
Date Opened: 04/16/2008

Site Address:
Hill Crane Service Inc.
Air Express Hwy & Us 395
Adelanto, CA 92301

Mailing Address:
2675 S Willow Avenue, Bloomington, CA 92316

Union Status: Union

SIC:7353

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/2008

Emphasis:

Case Closed: 08/07/2012


Related Activity
Type Activity Nr Safety Health
Accident 102551348
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $2,925 $0 $0 $1,300 $0 $4,225
Current Penalty $2,925 $0 $0 $0 $0 $2,925
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4940 09/26/2008 10/10/2008 $0 $650 $0 10/20/2008 F - Formal Settlement  
2. 01002 Other 2946 B03 09/26/2008 10/10/2008 $0 $650 $0 10/20/2008 F - Formal Settlement  
3. 02001 Serious 1509 A 09/26/2008 10/10/2008 $2,925 $2,925 $0 10/20/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202448015
Event: 04/16/2008
Employee Is Killed by Contact with Overhead Powerlines

At 10:06 p.m. on April 16, 2008, a fatality (electrocution) occurred at Hill Carne Services, Inc. The employer had total of 66 employees and was unionized (International Union of Operating Engineers, Local-12). At the time of accident, Employee #1 was operating a mobile crane (Terex Crane, Model T340XL, Serial Number 51634, license number ZRN561) under overhead high voltage power lines (12 kilovolt). The boom of the crane was extended to load K-rails to a flatbed truck, while the portable tower light was off. Employee #1 was backing up after the fourth K-rail was loaded when the boom of the crane contacted the overhead high voltage power lines and energized the crane. The boom knocked down two of the three conductors. Employee #1 jumped out of the cab, grabbed a shovel, and tried to put out the resulting fire with dirt from underneath the crane truck. Employee #1 noticed the fire in the rear section of the truck. As Employee #1 went to look underneath the crane on his hands and knees, inadvertently he touched the energized outrigger and collapsed. Employee #1 was pronounced dead at the hospital at 10:49 p.m.

Keywords: OVERHEAD POWER LINE, OUTRIGGER, BOOM, ELECTROCUTED, FIRE, MOBILE CRANE, CRANE OPERATOR, SHOVEL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310602487 Fatality Electric Shock Crane and tower operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.