Powered by GoogleTranslate

Inspection Detail

Inspection: 310586193 - P & M Home Improvements, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 310586193
Report ID: 0352410
Date Opened: 01/04/2007

Site Address:
P & M Home Improvements, Inc.
Matapeake Middle School, 651 Romancoke Road
Stevensville, MD 21666

Mailing Address:
7 Knoll Side Lane, Middletown, MD 21769

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/23/2007

Planning Guide: Safety-Construction

Emphasis: S:Construction, S:Falls

Case Closed: 03/29/2007


Related Activity
Type Activity Nr Safety Health
Accident 102360328
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $3,800 $0 $0 $0 $0 $3,800
Current Penalty $2,400 $0 $0 $0 $0 $2,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260501 B04 I 02/21/2007 02/26/2007 $1,900 $2,900 $0 I - Informal Settlement  
2. 02001 Serious 19260501 B10 02/21/2007 02/26/2007 $500 $900 $0 I - Informal Settlement  
3. 03001 Other 19260503 B01 02/21/2007 02/26/2007 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202361945
Event: 01/04/2007
Employee Is Killed in Fall from Roof

On January 4, 2007, an employee and three coworkers had installed roofing felt on a reverse A roof with a 4-in 12 slope. Located on each side of the roof were 4 skylight openings that measured approximately 4-ft long by 4-ft wide. There were total of 8 skylights that were covered with the roof felt and marked with orange spray paint. The employee stepped backwards and fell through the inadequately covered skylight opening. He fell 30 feet 8 inches to a concrete floor below and landed on his face. The employee was pronounced dead on the scene. The coworkers that were interviewed at the site stated that they were utilizing full body harnesses with lanyards attached to rope grabs that were attached at the peak for fall protection. One coworker stated that the roof anchors were removed to allow for the last row of roof felt to be installed that went on the peak of the roof and covered both sides of the roof.

Keywords: SKYLIGHT, HEAD, ROOF, FALL, FALL PROTECTION, WORK SURFACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310586193 Fatality Other Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.